Product Details | POWER TRANSFORMER

5950-01-273-3020 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: 4025, 4-025, 5950-01-273-3020, 01-273-3020, 5950012733020, 012733020

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 23 FEB 1988 01-273-3020

Cross Reference | NSN 5950-01-273-3020

Part Number Cage Code Manufacturer
4-025 50290 ELECTRO SWITCH CORP. DBA ARGA CONTROLS A UNIT OF ELECTRO

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-273-3020

Technical Data | NSN 5950-01-273-3020

Characteristic Specifications
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
MOUNTING METHOD UNTHREADED HOLE SINGLE GROUP
MOUNTING HOLE DIAMETER 0.250 INCHES NOMINAL SINGLE GROUP
WINDING OPERATING VOLTAGE 120.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
TERMINAL TYPE AND QUANTITY 1 TERMINAL BLOCK W/SCREWS
WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT
RELIABILITY INDICATOR NOT ESTABLISHED
BODY WIDTH 2.000 INCHES NOMINAL
BODY LENGTH 3.630 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
WINDING OPERATING CURRENT 0.0 MILLIAMPERES DC MINIMUM SINGLE COMPONENT SINGLE SECONDARY AND 1.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
BODY HEIGHT 4.000 INCHES NOMINAL
FREQUENCY RATING 60.0 HERTZ NOMINAL SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
INCLOSURE TYPE FULLY INCLOSED

Restrictions/Controls & Freight Information | NSN 5950-01-273-3020

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information