NSN 5950-01-299-4413 1809665, 2416120, 241-6-120
Product Details | POWER TRANSFORMER
5950-01-299-4413 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station
Part Alternates: 1809665, 2416120, 241-6-120, 5950-01-299-4413, 01-299-4413, 5950012994413, 012994413
Electrical and Electronic Equipment Components | Coils and Transformers
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 01 MAY 1989 | 01-299-4413 | 32496 ( TRANSFORMER, POWER ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5950-01-299-4413
Technical Data | NSN 5950-01-299-4413
| Characteristic | Specifications |
|---|---|
| TERMINAL TYPE AND QUANTITY | 5 QUICK DISCONNECT, FEMALE OR 5 TAB, SOLDER LUG |
| (NON-CORE DATA) WINDING TAP LOCATION | CENTER TAP SINGLE COMPONENT SINGLE SECONDARY |
| WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY 120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| WINDING OPERATING CURRENT | 250.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| FREQUENCY RATING | 50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
| MAXIMUM TRANSFORMER POWER RATING | 30.0 VOLT-AMPERE SINGLE COMPONENT |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| MOUNTING METHOD | FLANGE AND UNTHREADED HOLE SINGLE GROUP |
| MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
| MOUNTING HOLE DIAMETER | 0.127 INCHES MINIMUM AND 0.247 INCHES MAXIMUM SINGLE GROUP |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.752 INCHES MINIMUM AND 2.872 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| INCLOSURE TYPE | FULLY INCLOSED |
| OVERALL LENGTH | 3.190 INCHES MINIMUM AND 3.310 INCHES MAXIMUM |
| OVERALL HEIGHT | 1.880 INCHES MINIMUM AND 2.000 INCHES MAXIMUM |
| OVERALL WIDTH | 1.630 INCHES MINIMUM AND 1.750 INCHES MAXIMUM |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| III MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
| (NON-CORE DATA) UNPACKAGED UNIT WEIGHT | 1.100 POUNDS |
| (NON-CORE DATA) CUBIC MEASURE | 11.6 CUBIC INCHES |
Restrictions/Controls & Freight Information | NSN 5950-01-299-4413
| Category | Code | Description |
|---|---|---|
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||