Product Details | POWER TRANSFORMER

5950-01-339-5097 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: FTC 3408, FTC3408, 350621, 35062-1, 5950-01-339-5097, 01-339-5097, 5950013395097, 013395097

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 23 MAY 1991 01-339-5097

Cross Reference | NSN 5950-01-339-5097

Part Number Cage Code Manufacturer
35062-1 09004 TRANSISTOR DEVICES, INC. DBA TDI POWER
FTC 3408 3S657 TRANSISTOR DEVICES INC DBA FERNWOOD MAGNETICS DIV DIV

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-339-5097

Technical Data | NSN 5950-01-339-5097

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 15 TAB, SOLDER LUG
(NON-CORE DATA) WINDING TAP LOCATION CENTER TAP SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE 40.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY 40.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY 20.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY 35.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY 250.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT 0.75 AMPERES DC NOMINAL SINGLE COMPONENT 1ST SECONDARY 0.4 AMPERES DC NOMINAL SINGLE COMPONENT 2ND SECONDARY 7.0 AMPERES DC NOMINAL SINGLE COMPONENT 3RD SECONDARY 0.05 AMPERES DC NOMINAL SINGLE COMPONENT 4TH SECONDARY 0.8 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING POWER RATING 30.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY 16.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY 140.0 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY 1.75 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY 200.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY
FREQUENCY RATING 47.0 HERTZ MINIMUM AND 63.0 HERTZ MAXIMUM SINGLE COMPONENT
WINDING SHIELDING METHOD PRIMARY AND SECONDARY SHIELDED AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 5 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD SLOT SINGLE GROUP
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
MOUNTING SLOT WIDTH 0.257 INCHES NOMINAL SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 3.180 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE FULLY INCLOSED
OVERALL LENGTH 3.880 INCHES MAXIMUM
OVERALL HEIGHT 3.250 INCHES MAXIMUM
OVERALL WIDTH 3.350 INCHES MAXIMUM
RELIABILITY INDICATOR NOT ESTABLISHED
SPECIAL FEATURES ONE PRIMARY WINDING; 5 SECONDARY WINDINGS
III MAXIMUM OPERATING TEMP 60.0 DEG CELSIUS
(NON-CORE DATA) UNPACKAGED UNIT WEIGHT 6.250 POUNDS
III HAZARDOUS LOCATIONS/ENVIRONMENTAL HUMIDITY RESISTANT

Restrictions/Controls & Freight Information | NSN 5950-01-339-5097

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-01-339-5097

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each