Product Details | REACTOR

5950-01-370-4855 A coil or coils usually constructed with cores having low magnetic reluctance, whose primary purpose is to furnish an inductive impedance in power or audio frequency circuit ranging from zero to 20 kilohertz (kilocycles). Includes audio frequency and power filter chokes, audio reactors and swinging chokes. Does not include transformers or coils used above audio frequency range. Excludes SATURABLE REACTOR. For reactors with air cores, see COIL (as modified).

Part Alternates: 15174, 48153601, 481536-01, 5950-01-370-4855, 01-370-4855, 5950013704855, 013704855

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 23 JAN 1993 01-370-4855

Cross Reference | NSN 5950-01-370-4855

Part Number Cage Code Manufacturer
15174 53854 MAGNESPEC, INC.
481536-01 03550 VANGUARD ELECTRONICS COMPANY
481536-01 07690 BAE SYSTEMS CONTROLS INC
481536-01 09798 PAYNE MAGNETICS, INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-370-4855

Technical Data | NSN 5950-01-370-4855

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 2 WIRE HOOK
RATING METHOD ELECTRICAL SINGLE COMPONENT SINGLE WINDING
WINDING OPERATING CURRENT 2.0 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING
DC RESISTANCE RATING IN OHMS 2.500 SINGLE COMPONENT SINGLE WINDING
INDUCTANCE RATING 100.00 MILLIHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING
FREQUENCY RATING 0.0 HERTZ MINIMUM AND 50.0 KILOHERTZ MAXIMUM ALL COMPONENTS
WINDING QUANTITY 1 ALL COMPONENTS
INDUCTANCE TYPE FIXED
MOUNTING METHOD UNTHREADED HOLE ALL GROUPINGS
MOUNTING FACILITY QUANTITY 4 ALL GROUPINGS
MOUNTING HOLE DIAMETER 0.165 INCHES MINIMUM AND 0.171 INCHES MAXIMUM ALL GROUPINGS
DISTANCE BETWEEN MOUNTING FACILITY CENTERS 2.028 INCHES NOMINAL SINGLE MOUNTING FACILITY 1ST CENTER GROUP 1.496 INCHES NOMINAL SINGLE MOUNTING FACILITY 2ND CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.028 INCHES NOMINAL ALL MOUNTING FACILITIES ALL CENTER GROUPINGS
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.496 INCHES NOMINAL ALL MOUNTING FACILITIES ALL CENTER GROUPINGS
INCLOSURE TYPE OPEN
BODY LENGTH 2.940 INCHES MAXIMUM
BODY HEIGHT 1.120 INCHES MAXIMUM
BODY WIDTH 1.810 INCHES MAXIMUM
RELIABILITY INDICATOR NOT ESTABLISHED
SPECIFICATION/STANDARD DATA 07690-481536 MANUFACTURERS SOURCE CONTROL
MANUFACTURERS CODE 07690
MFR SOURCE CONTROLLING REFERENCE 481536-01

Restrictions/Controls & Freight Information | NSN 5950-01-370-4855

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063498 VOICE COIL/DYNAMIC LOUDSPEAKER
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-01-370-4855

Category Code Description
Stores Account Code1Marine Corps Stock Fund Account Item.
Combat Essentiality Code5Critical Repair Part to a Combat Essential End Item. Those parts or components whose failure in a combat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency.
Materiel Management CodeBAll CommoditiesDefense Logistics Agency, (DLA,)
Echelon Management Code2ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDMU.S. Marine Corps
Service OrganizationMU.S. Marine Corps
ReparabilityZNonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code.
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each