Product Details | POWER TRANSFORMER

5950-01-409-1891 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: 310CC16700, 5950-01-409-1891, 01-409-1891, 5950014091891, 014091891

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 01-409-1891

Demand History | NSN 5950-01-409-1891

Part Number Request Date QTY Origin
5950-01-409-1891 2020-10-283 2 us
5950-01-409-1891 2008-05-132 1 DIBBS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-409-1891

Technical Data | NSN 5950-01-409-1891

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 19 PIN
(NON-CORE DATA) WINDING TAP LOCATION TAP W/O CENTER TAP SINGLE COMPONENT 1ST PRIMARY CENTER TAP SINGLE COMPONENT ALL SECONDARY
WINDING OPERATING VOLTAGE 100.00 AC VOLTS NOMINAL AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY 47.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY 18.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY 45.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY 7.50 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING CURRENT 0.5 AMPERES DC MINIMUM AND 3.0 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY 5.0 AMPERES DC NOMINAL SINGLE COMPONENT 2ND SECONDARY 0.02 AMPERES DC NOMINAL SINGLE COMPONENT 3RD SECONDARY 0.075 AMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY
FREQUENCY RATING 50.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING SHIELDING METHOD CORE GROUNDED AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 2 PRIMARY AND 4 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD THREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
THREAD SERIES DESIGNATOR UNC SINGLE GROUP
NOMINAL THREAD SIZE 0.164 INCHES SINGLE GROUP
(NON-CORE DATA) THREAD CLASS 2B SINGLE GROUP
(NON-CORE DATA) THREAD DIRECTION RIGHT-HAND SINGLE GROUP
INCLOSURE TYPE FULLY INCLOSED
BODY HEIGHT 4.000 INCHES NOMINAL
OVERALL LENGTH 3.750 INCHES NOMINAL
OVERALL WIDTH 3.250 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED
(NON-CORE DATA) DUMMY TERMINAL QUANTITY 4
III MAXIMUM OPERATING TEMP 65.0 DEG CELSIUS

Restrictions/Controls & Freight Information | NSN 5950-01-409-1891

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Category Code Description
No Freight Information