NSN 5960-00-185-8757 7476737P11, 00-185-8757, 001858757
Product Details | ELECTRON TUBE RETAINER
5960-00-185-8757 An item specifically designed to restrain the movement of an electron tube when the latter is mounted in another item, normally a tube socket. Includes clamps, clips, and similar restraining devices specifically designed for this function.
Part Alternates: 7476737P11, 5960-00-185-8757, 00-185-8757, 5960001858757, 001858757
Electrical and Electronic Equipment Components | Electron Tubes and Associated Hardware
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 24 FEB 1971 | 00-185-8757 | 16182 ( RETAINER, ELECTRON TUBE ) |
Cross Reference | NSN 5960-00-185-8757
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 7476737P11 | 03538 | LOCKHEED MARTIN CORPORATION DIV MST |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5960-00-185-8757
Related Products | NSN 5960-00-185-8757
Technical Data | NSN 5960-00-185-8757
| Characteristic | Specifications |
|---|---|
| MATERIAL | STEEL COMP 301 |
| STYLE DESIGNATOR | 21B SINGLE FOOT, CLIP LOCKED, TENSION CLAMP |
| INSIDE DIAMETER | 1.660 INCHES NOMINAL |
| OVERALL HEIGHT | 0.750 INCHES NOMINAL |
| DISTANCE FROM RETAINER CENTER TO CENTERLINE OF MOUNTING FACILITY | 1.047 INCHES NOMINAL |
| DISTANCE FROM RETAINER CENTER TO END OF EXTENDED CLIP | 1.703 INCHES NOMINAL |
| ANGLE BETWEEN MOUNTING FACILITY AND TENSION LOOP CENTERLINES IN DEG | 45.0 |
| ANGLE BETWEEN MOUNTING FACILITY AND LOOP HINGE CENTERLINES IN DEG | 170.0 |
| REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AS DIFFERENTIATED BY NAVORD OD41152 |
| CRITICALITY CODE JUSTIFICATION | ZZZY |
| MANUFACTURERS CODE | 03538 |
| DESIGN CONTROL REFERENCE | 7476737P11 |
Restrictions/Controls & Freight Information | NSN 5960-00-185-8757
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | D | Munitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.) |
| Controlled Inventory Item Code: | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | Y | The item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061680 | ELEC WIRING PLUGS ETC |
| Less than car load rating | ||
| Less than truck load rating | W | Rating Variable |
| Water commodity Code | 657 | unknown |
| Originating Activity Code | HH | Navy ICP Mechanicsburg, PA 17055-0788 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5960-00-185-8757
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
| Special Material ID | SP | Navy Stock Account item which is unique to SSPO controlled fleet ballistic missile weapon system program. SMIC SP establishes a weapons system relationship. |
| Special Material Content | 9 | Non-Hazardous or Non-Sensitive Item, does not require hazardous or special handling, packaging or precautions |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
| Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |