Product Details | ELECTRON TUBE

5960-01-280-9956 An inclosure, including two or more electrodes, in which a flow of electrons may occur through a vacuum or a contained gas. The electronic conduction takes place either by means of electrons emitted from a cathode or by ionization of the contained gas. Includes phototubes (photoemissive type only), Geiger-Mueller tubes, traveling wave tubes, cathode ray tubes and microwave tubes (Klystron, magnetron, or the like). Excludes items whose primary purpose is to produce light energy. Also excludes PHOTOELECTRIC CELL; and SEMICONDUCTOR DEVICE (as modified).

Part Alternates: 1397991, 139799-1, 5960-01-280-9956, 01-280-9956, 5960012809956, 012809956

Electrical and Electronic Equipment Components | Electron Tubes and Associated Hardware

Supply Group (FSG) NSN Assign. NIIN
59 16 JUN 1988 01-280-9956

Cross Reference | NSN 5960-01-280-9956

Part Number Cage Code Manufacturer
139799-1 10138 ASTRONAUTICS CORPORATION OF AMERICA

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5960-01-280-9956

Technical Data | NSN 5960-01-280-9956

Characteristic Specifications
TUBE TYPE CATHODE RAY
SPECIAL FEATURES APPLICATION DATA:DISPLAY UNIT
END ITEM IDENTIFICATION TA-7C ACFT
MANUFACTURERS CODE 10138
DESIGN CONTROL REFERENCE 139799-1

Restrictions/Controls & Freight Information | NSN 5960-01-280-9956

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:NThe item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input).
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 063473 TUBES CATHODE RAY,TRANSMITTING SUB1
Less than car load rating H 110
Less than truck load rating H 110.0
Water commodity Code 724 unknown
Originating Activity Code KE Naval ICP
Philadelphia, PA 19111
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5960-01-280-9956

Category Code Description
Cognizance Codes7RAeronautical Depot Level Repairable Spares
Naval Inventory Control Point, Philadelphia
Special Material IDUAATTACKAIRCRAFT(TA-7C)
Issue Repair, or RequisitionARRepairable item subject to centrally managed rework program at designated sites. Mandatory turn-in of item required except when initial issue or replacement of surveyed item is involved.
Special Material Content2 Electrostatic Discharge (ESD)/Electromagnetic (EM) Sensitive Item
Source of SupplyNRPNAVICP-ERP
700 Robbins Avenue
Philadelphia, PA 19111-5098
AgencyDNDepartment of the Navy
Service OrganizationLLead Service - 22 (Repairable)
ReparabilityHDepot Level Reparable
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative