NSN 5961-00-203-0017 00-203-0017, 002030017
Product Details | TRANSISTOR
5961-00-203-0017 An active semiconductor device with three or more electrodes. May or may not include mounting hardware and/or heatsink. Excludes SEMICONDUCTOR DEVICE, DIODE and SEMICONDUCTOR DEVICE, THYRISTOR. For solid state devices which are responsive to visible or infrared radiant energy, see SEMICONDUCTOR DEVICE, PHOTO.
Part Alternates: 5961-00-203-0017, 00-203-0017, 5961002030017, 002030017
Electrical and Electronic Equipment Components | Semiconductor Devices and Associated Hardware
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 00-203-0017 | 20588 ( TRANSISTOR ) |
Cross Reference | NSN 5961-00-203-0017
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 03-2N3440-X | 94987 | CUBIC DEFENSE APPLICATIONS, INC. |
| 14-815-12 | 02324 | ELECTROHOME LTD |
| 14-815-12 | 54063 | COMMERCIAL ELECTRONICS INC |
| 1854-0234 | 80131 | ELECTRONIC INDUSTRIES ASSOCIATION |
| 20-00315-001 | 00724 | RAYTHEON COMPANY DBA RAYTHEON |
| 2N3440 | 07688 | JOINT ELECTRON DEVICE ENGINEERING COUNCIL |
| 2N3440 | 12735 | COMPUTER MICROTECHNOLOGY INC |
| 2N3440 | 13859 | KING NUTRONICS CORPORATION |
| 2N3440 | 23859 | INTEGRO, LLC |
| 2N3440 | 32159 | WEST CAP ARIZONA |
| 2N3440 | 38864 | CANADIAN CURTIS REFRIGERATION INC |
| 2N3440 | 59993 | INTERNATIONAL RECTIFIER CORPORATION Use CAGE Code 81483 for cataloging |
| 2N3440 | 95295 | MISSISSIPPI LIME COMPANY DBA FALCO LIME |
| 2N3440 | 96906 | MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS |
| 352-7500-461 | 13499 | ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS |
| 352-8011-190 | 13499 | ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS |
| 36872 | 34371 | INTERSIL CORPORATION |
| 534412-1 | 96214 | RAYTHEON COMPANY DBA RAYTHEON |
| 534412-2 | 96214 | RAYTHEON COMPANY DBA RAYTHEON |
| 60090-148 | 12763 | DYNALEC CORPORATION |
| 7906500-00 | 90536 | LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN |
| A163B4-31 | 35918 | HORIZON AEROSPACE LLC DBA MAGNETICS DIVISION |
| BF338 | 73445 | AMPEREX ELECTRONIC CORP |
| C09644-0003 | 59885 | ROSEMOUNT AEROSPACE INC. DBA A UTC AEROSPACE SYSTEMS COMPANY |
| C09644-0003 | 60678 | ROSEMOUNT AEROSPACE INC. DBA ROSEMOUNT AEROSPACE DIVISION |
| G-1149-JTX | 28199 | L-3 COMMUNICATIONS CORPORATION DBA L-3 HENSCHEL |
| JAN2N3440 | 81350 | JOINT ARMY-NAVY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS |
| JAN2N3440J | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
| JANTX2N3440 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
| JANTX2N3440A | C7191 | ADELCO ELEKTRONIK GMBH |
| MIL-PRF-19500/368 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
| TX2N3440 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5961-00-203-0017
Related Products | NSN 5961-00-203-0017
Technical Data | NSN 5961-00-203-0017
| Characteristic | Specifications |
|---|---|
| SEMICONDUCTOR MATERIAL | SILICON |
| INTERNAL CONFIGURATION | JUNCTION CONTACT |
| INTERNAL JUNCTION CONFIGURATION | NPN |
| VOLTAGE RATING IN VOLTS PER CHARACTERISTIC | 450.0 MAXIMUM COLLECTOR TO BASE VOLTAGE, DC AND 350.0 MAXIMUM COLLECTOR TO EMITTER VOLTAGE/STATIC/BASE OPEN AND 7.0 MAXIMUM EMITTER TO BASE VOLTAGE, DC |
| CURRENT RATING PER CHARACTERISTIC | 1.00 AMPERES MAXIMUM COLLECTOR CURRENT, DC |
| POWER RATING PER CHARACTERISTIC | 800.0 MILLIWATTS MAXIMUM COLLECTOR POWER DISSIPATION |
| MAXIMUM OPERATING TEMP PER MEASUREMENT POINT | 200.0 DEG CELSIUS JUNCTION |
| INCLOSURE MATERIAL | METAL |
| MOUNTING METHOD | TERMINAL |
| TERMINAL LENGTH | 1.500 INCHES MINIMUM |
| TERMINAL CIRCLE DIAMETER | 0.200 INCHES NOMINAL |
| TERMINAL TYPE AND QUANTITY | 3 UNINSULATED WIRE LEAD |
| OVERALL LENGTH | 0.250 INCHES NOMINAL |
| OVERALL DIAMETER | 0.335 INCHES MAXIMUM |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE |
Restrictions/Controls & Freight Information | NSN 5961-00-203-0017
| Category | Code | Description |
|---|---|---|
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||