NSN 5961-00-621-7554 G517102 , RCA62983, 1398306
Product Details | TRANSISTOR
5961-00-621-7554 An active semiconductor device with three or more electrodes. May or may not include mounting hardware and/or heatsink. Excludes SEMICONDUCTOR DEVICE, DIODE and SEMICONDUCTOR DEVICE, THYRISTOR. For solid state devices which are responsive to visible or infrared radiant energy, see SEMICONDUCTOR DEVICE, PHOTO.
Part Alternates: G517102 , RCA62983, 1398306, 2N6099 , 2N6099A, 4901060990, 4901-06-0990, 62983, 5961-00-621-7554, 00-621-7554, 5961006217554, 006217554
Electrical and Electronic Equipment Components | Semiconductor Devices and Associated Hardware
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 27 FEB 1975 | 00-621-7554 | 20588 ( TRANSISTOR ) |
Cross Reference | NSN 5961-00-621-7554
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 2N6099 | 1MY79 | INTERSIL COMMUNICATIONS INC. |
| 2N6099 | 34371 | INTERSIL CORPORATION |
| 2N6099 | C7191 | ADELCO ELEKTRONIK GMBH |
| 2N6099A | C7191 | ADELCO ELEKTRONIK GMBH |
| 4901-06-0990 | 34280 | WAVETEK RF PRODUCTS INC |
| 62983 | 1MY79 | INTERSIL COMMUNICATIONS INC. |
| 62983 | 34371 | INTERSIL CORPORATION |
| RCA62983 | 07076 | LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN SIMULATION |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5961-00-621-7554
Related Products | NSN 5961-00-621-7554
Technical Data | NSN 5961-00-621-7554
| Characteristic | Specifications |
|---|---|
| SEMICONDUCTOR MATERIAL | SILICON |
| INTERNAL CONFIGURATION | JUNCTION CONTACT |
| VOLTAGE RATING IN VOLTS PER CHARACTERISTIC | 70.0 MAXIMUM BREAKDOWN VOLTAGE, COLLECTOR-TO-BASE, EMITTER OPEN AND 8.0 MAXIMUM EMITTER TO BASE VOLTAGE, STATIC, COLLECTOR OPEN AND 60.0 MAXIMUM BREAKDOWN VOLTAGE, COLLECTOR-TO-EMITTER, BASE OPEN |
| CURRENT RATING PER CHARACTERISTIC | 10.00 AMPERES MAXIMUM COLLECTOR CURRENT, DC AND 4.00 AMPERES MAXIMUM BASE CURRENT, DC |
| POWER RATING PER CHARACTERISTIC | 75.0 WATTS MAXIMUM COLLECTOR POWER DISSIPATION |
| TRANSFER RATIO | 80.0 MAXIMUM STATIC FORWARD CURRENT TRANSFER RATIO, COMMON-EMITTER |
| MAXIMUM OPERATING TEMP PER MEASUREMENT POINT | 165.0 DEG CELSIUS JUNCTION |
| INCLOSURE MATERIAL | PLASTIC |
| JOINT ELECTRONIC DEVICE ENGINEERING COUNCIL/JEDEC/CASE OUTLINE DESIGNATION | TO-220 |
| MOUNTING METHOD | UNTHREADED HOLE |
| MOUNTING FACILITY QUANTITY | 1 |
| TERMINAL TYPE AND QUANTITY | 3 UNINSULATED WIRE LEAD |
| OVERALL LENGTH | 0.650 INCHES MAXIMUM |
| OVERALL HEIGHT | 0.190 INCHES MAXIMUM |
| OVERALL WIDTH | 0.420 INCHES MAXIMUM |
| SPECIAL FEATURES | JUNCTION PATTERN ARRANGEMENT: NPN |
Restrictions/Controls & Freight Information | NSN 5961-00-621-7554
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | U | Precious metal type is unknown |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 063025 | SEMICONDUCTORS/DEVICES NOI ETC |
| Less than car load rating | ||
| Less than truck load rating | W | Rating Variable |
| Water commodity Code | 72D | unknown |
| Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5961-00-621-7554
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 7H | Depot level reparable shipboard and base equipment, assemblies, components and repair parts related to Naval Sea Systems Command equipment Naval Inventory Control Point, Mechanicsburg |
| Issue Repair, or Requisition | C0 | Critical item. Do not issue. Refer all requests to cognizant manager. |
| Special Material Content | 9 | Non-Hazardous or Non-Sensitive Item, does not require hazardous or special handling, packaging or precautions |
| Cognizance Codes | 9N | Navy-owned stocks of defense electronic material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | NRP | NAVICP-ERP 700 Robbins Avenue Philadelphia, PA 19111-5098 |
| Agency | DN | Department of the Navy |
| Service Organization | L | Lead Service - 22 (Repairable) |
| Reparability | H | Depot Level Reparable |
| Acquisition Advice Codes | C | SERVICE/AGENCY-MANAGED (Service/Agency use only.) # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures. |
| Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
| Shelf Life Code | 0 | Nondeteriorative |
| Source of Supply | S9E | Defense Supply Center Columbus Columbus, OH 43218 |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |