NSN 5961-01-097-4999 616318-902, 01-097-4999, 616318902
Product Details | TRANSISTOR
5961-01-097-4999 An active semiconductor device with three or more electrodes. May or may not include mounting hardware and/or heatsink. Excludes SEMICONDUCTOR DEVICE, DIODE and SEMICONDUCTOR DEVICE, THYRISTOR. For solid state devices which are responsive to visible or infrared radiant energy, see SEMICONDUCTOR DEVICE, PHOTO.
Part Alternates: 616318-902, 5961-01-097-4999, 01-097-4999, 5961010974999, 616318902, 010974999
Electrical and Electronic Equipment Components | Semiconductor Devices and Associated Hardware
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 14 JUL 1980 | 01-097-4999 | 20588 ( TRANSISTOR ) |
Cross Reference | NSN 5961-01-097-4999
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 616318-902 | 37695 | RAYTHEON COMPANY DBA RAYTHEON |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5961-01-097-4999
Related Products | NSN 5961-01-097-4999
Technical Data | NSN 5961-01-097-4999
| Characteristic | Specifications |
|---|---|
| SEMICONDUCTOR MATERIAL | SILICON |
| INTERNAL CONFIGURATION | FIELD EFFECT |
| (NON-CORE DATA) CHANNEL POLARITY AND CONTROL TYPE | N-CHANNEL INSULATED GATE TYPE |
| POWER RATING PER CHARACTERISTIC | 8.3 WATTS MAXIMUM PEAK GATE POWER-FORWARD |
| MAXIMUM OPERATING TEMP PER MEASUREMENT POINT | 150.0 DEG CELSIUS AMBIENT AIR |
| INCLOSURE MATERIAL | METAL |
| ELECTRODE INTERNALLY-ELECTRICALLY CONNECTED TO CASE | DRAIN |
| JOINT ELECTRONIC DEVICE ENGINEERING COUNCIL/JEDEC/CASE OUTLINE DESIGNATION | T0-39 |
| MOUNTING METHOD | TERMINAL |
| TERMINAL LENGTH | 0.500 INCHES NOMINAL |
| TERMINAL CIRCLE DIAMETER | 0.200 INCHES NOMINAL |
| TERMINAL TYPE AND QUANTITY | 3 UNINSULATED WIRE LEAD |
| OVERALL LENGTH | 0.240 INCHES MINIMUM AND 0.260 INCHES MAXIMUM |
| OVERALL DIAMETER | 0.350 INCHES MINIMUM AND 0.370 INCHES MAXIMUM |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE |
| MANUFACTURERS CODE | 37695 |
| DESIGN CONTROL REFERENCE | 616318-902 |
Restrictions/Controls & Freight Information | NSN 5961-01-097-4999
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | Q | Strategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.” |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| NMF Description | 060500 | ELECTRICAL EQUIPMENT GROUP |
| Less than car load rating | ||
| Less than truck load rating | Z | No Rating |
| Water commodity Code | 72D | unknown |
| Originating Activity Code | KE | Naval ICP Philadelphia, PA 19111 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5961-01-097-4999
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
| Special Material Content | 2 | Electrostatic Discharge (ESD)/Electromagnetic (EM) Sensitive Item |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |



