Product Details | LINEAR MICROCIRCUIT

5962-01-213-3899 A microcircuit whose output is a function of the input; that is, the output varies in a predetermined and essentially predictable manner from the input signal.

Part Alternates: AD1403A, 445/4/12461/000, 445412461000, 5962-01-213-3899, 01-213-3899, 5962012133899, 012133899

Electrical and Electronic Equipment Components | Microcircuits, Electronic

Supply Group (FSG) NSN Assign. NIIN
59 25 JUL 1985 01-213-3899

Cross Reference | NSN 5962-01-213-3899

Part Number Cage Code Manufacturer
445/4/12461/000 K3902 BAE SYSTEMS MARITIME SERVICES
445/4/12461/000 U4290 G E C MARCONI S3I LTD COMBAT SYSTEMS IVISION
AD1403A 24355 ANALOG DEVICES, INC. DIV CORPORATE HEADQUARTERS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5962-01-213-3899

Technical Data | NSN 5962-01-213-3899

Characteristic Specifications
DESIGN FUNCTION AND QUANTITY 1 REFERENCE, VOLTAGE, ANALOG
INPUT CIRCUIT PATTERN 1 INPUT
VOLTAGE RATING AND TYPE PER CHARACTERISTIC 40.0 VOLTS NOMINAL INPUT
OPERATING TEMP RANGE 0.0 TO 70.0 DEG CELSIUS
TERMINAL TYPE AND QUANTITY 8 PRINTED CIRCUIT
TERMINAL SURFACE TREATMENT SOLDER
INCLOSURE CONFIGURATION DUAL-IN-LINE
INCLOSURE MATERIAL METAL
PART NAME ASSIGNED BY CONTROLLING AGENCY LOW COST, PRECISION 2.5 V IC REFERENCE
BODY LENGTH 0.390 INCHES MAXIMUM
BODY HEIGHT 0.180 INCHES MAXIMUM
BODY WIDTH 0.250 INCHES NOMINAL
STORAGE TEMP RANGE -65.0 TO 150.0 DEG CELSIUS

Restrictions/Controls & Freight Information | NSN 5962-01-213-3899

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Electro-static Discharge Susceptible:BESD sensitivity
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description