Product Details | DIGITAL MICROCIRCUIT

5962-01-223-6451 A microcircuit specifically designed to generate, modify, or process electrical signals which operate with two distinct or binary states. These states are commonly referred to as on and off, true and false, high and low, or "1" and "0".

Part Alternates: PAL20L10AMJS/BZ4005, PAL20L10AMJSBZ4005, PAL20L10MJ883B, PCU33, ROM/PROM, ROMPROM, 68320005021, 68320005-021, 68320010, 5962-01-223-6451, 01-223-6451, 5962012236451, 012236451

Electrical and Electronic Equipment Components | Microcircuits, Electronic

Supply Group (FSG) NSN Assign. NIIN
59 04 JAN 1986 01-223-6451

Cross Reference | NSN 5962-01-223-6451

Part Number Cage Code Manufacturer
68320005-021 04939 LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN
68320005-021 7H140 TEKTRONIX SERVICE SOLUTIONS INC.
68320010 04939 LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN
PAL20L10AMJS/BZ4005 50364 MMI/AMD
PAL20L10MJ883B 50364 MMI/AMD
PCU33 04939 LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN
ROM/PROM 16236 DLA LAND AND MARITIME

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5962-01-223-6451

Technical Data | NSN 5962-01-223-6451

Characteristic Specifications
END ITEM IDENTIFICATION AN/TSQ-111
DESIGN FUNCTION AND QUANTITY 1 ARRAY, LOGIC
BODY WIDTH 0.550 INCHES MAXIMUM
FEATURES PROVIDED HERMETICALLY SEALED AND BURN IN AND BIPOLAR AND PROGRAMMABLE AND ELECTROSTATIC SENSITIVE
TERMINAL SURFACE TREATMENT SOLDER
INPUT CIRCUIT PATTERN 12 INPUT
TERMINAL TYPE AND QUANTITY 16 PRINTED CIRCUIT
VOLTAGE RATING AND TYPE PER CHARACTERISTIC 7.0 VOLTS MAXIMUM POWER SOURCE
TIME RATING PER CHACTERISTIC ERR-060 NOMINAL HAND PULL AND ERR-060 NOMINAL HAND
BODY LENGTH 1.290 INCHES MAXIMUM
BODY HEIGHT 0.195 INCHES MAXIMUM
INCLOSURE MATERIAL CERAMIC
TEST DATA DOCUMENT 96906-MIL-STD-883 STANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS, INDIVIDUAL MANUFACTUREER STANDARDS, ETC.).
STORAGE TEMP RANGE -65.0/+150.0 DEG CELSIUS
INCLOSURE CONFIGURATION DUAL-IN-LINE
OUTPUT LOGIC FORM TRANSISTOR-TRANSISTOR LOGIC
OPERATING TEMP RANGE -55.0/+125.0 DEG CELSIUS

Restrictions/Controls & Freight Information | NSN 5962-01-223-6451

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Electro-static Discharge Susceptible:BESD sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating P 77.5
Less than truck load rating W Rating Variable
Water commodity Code 72D unknown
Originating Activity Code TH Defense Supply Center Columbus
Columbus, OH 43215
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo 3 Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

Management | NSN 5962-01-223-6451

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Price ValidationE The current standard price is an estimated price.
  • Estimated Price challenges are allowed, but follow procedures in para 60.b. (3) of section L of this manual.
  • This code will be changed to a P code upon notification of a contract price or this code will be changed to an updated code upon determination of a valid price.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each