Product Details | DIGITAL MICROCIRCUIT

5962-01-232-6681 A microcircuit specifically designed to generate, modify, or process electrical signals which operate with two distinct or binary states. These states are commonly referred to as on and off, true and false, high and low, or "1" and "0".

Part Alternates: CD40106B/883, CD40106B883, CD40106BD/3, CD40106BD3, CD40106BF3A, 13207612, 5962-01-232-6681, 01-232-6681, 5962012326681, 012326681

Electrical and Electronic Equipment Components | Microcircuits, Electronic

Supply Group (FSG) NSN Assign. NIIN
59 19 MAY 1986 01-232-6681

Cross Reference | NSN 5962-01-232-6681

Part Number Cage Code Manufacturer
13207612 18876 U S ARMY AVIATION AND MISSILE COMMAND
CD40106B/883 34371 INTERSIL CORPORATION
CD40106BD/3 34371 INTERSIL CORPORATION
CD40106BF3A 34371 INTERSIL CORPORATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5962-01-232-6681

Technical Data | NSN 5962-01-232-6681

Characteristic Specifications
TEST DATA DOCUMENT 18876-13207612 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
STORAGE TEMP RANGE -65.0/+150.0 DEG CELSIUS
END ITEM IDENTIFICATION 1055-01-251-9756
OPERATING TEMP RANGE -55.0/+125.0 DEG CELSIUS

Restrictions/Controls & Freight Information | NSN 5962-01-232-6681

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Electro-static Discharge Susceptible:BESD sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 063025 SEMICONDUCTORS/DEVICES NOI ETC SUB1
Less than car load rating J 100.2
Less than truck load rating J 100.2
Water commodity Code 658 unknown
Originating Activity Code BD U.S. Army Aviation and Missile Command
Redstone Arsenal, AL 35898-5230
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable