Product Details | DIGITAL MICROCIRCUIT

5962-01-263-5738 A microcircuit specifically designed to generate, modify, or process electrical signals which operate with two distinct or binary states. These states are commonly referred to as on and off, true and false, high and low, or "1" and "0".

Part Alternates: AM2949PC, 5017596001, 5017596-001, 5962-01-263-5738, 01-263-5738, 5962012635738, 012635738

Electrical and Electronic Equipment Components | Microcircuits, Electronic

Supply Group (FSG) NSN Assign. NIIN
59 16 SEP 1987 01-263-5738

Cross Reference | NSN 5962-01-263-5738

Part Number Cage Code Manufacturer
5017596-001 K1182 THALES UK LIMITED DBA THALES UK LTDTRAINING AND SIMULATION
AM2949PC 34335 ADVANCED MICRO DEVICES, INC. DBA A M D

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5962-01-263-5738

Technical Data | NSN 5962-01-263-5738

Characteristic Specifications
OUTPUT LOGIC FORM TRANSISTOR-TRANSISTOR LOGIC
DESIGN FUNCTION AND QUANTITY 8 TRANSCEIVER
OPERATING TEMP RANGE 0.0 TO 70.0 DEG CELSIUS
INCLOSURE CONFIGURATION DUAL-IN-LINE
INCLOSURE MATERIAL PLASTIC
BODY LENGTH 1.000 INCHES MINIMUM AND 1.040 INCHES MAXIMUM
BODY HEIGHT 0.135 INCHES MINIMUM AND 0.140 INCHES MAXIMUM
BODY WIDTH 0.250 INCHES MINIMUM AND 0.290 INCHES MAXIMUM
FEATURES PROVIDED BIDIRECTIONAL AND SCHOTTKY AND 3-STATE OUTPUT AND LOW POWER

Restrictions/Controls & Freight Information | NSN 5962-01-263-5738

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information