Product Details | LINEAR MICROCIRCUIT

5962-01-284-0276 A microcircuit whose output is a function of the input; that is, the output varies in a predetermined and essentially predictable manner from the input signal.

Part Alternates: 10136466 , 259298, 3904869, 3905240, 39052401, 3905240-1, 656146, 5962-01-284-0276, 01-284-0276, 5962012840276, 012840276

Electrical and Electronic Equipment Components | Microcircuits, Electronic

Supply Group (FSG) NSN Assign. NIIN
59 18 AUG 1988 01-284-0276

Demand History | NSN 5962-01-284-0276

Part Number Request Date QTY Origin
5962-01-284-0276 2013-06-169 23 DIBBS
5962-01-284-0276 2012-07-188 30 DIBBS
5962-01-284-0276 2011-10-292 5 DIBBS
5962-01-284-0276 2009-11-305 30 DIBBS
5962-01-284-0276 2009-08-224 8 DIBBS
5962-01-284-0276 2009-07-183 10 DIBBS
5962-01-284-0276 2009-01-13 6 DIBBS
5962-01-284-0276 2009-01-05 20 DIBBS
5962-01-284-0276 2008-12-364 6 DIBBS
5962-01-284-0276 2008-12-354 20 DIBBS

Cross Reference | NSN 5962-01-284-0276

Part Number Cage Code Manufacturer
259298 82577 RAYTHEON COMPANY DBA RAYTHEON
3904869 82577 RAYTHEON COMPANY DBA RAYTHEON
3905240 82577 RAYTHEON COMPANY DBA RAYTHEON
3905240-1 4U884 RAYTHEON COMPANY DBA RAYTHEON
3905240-1 K5533 RAYTHEON SYSTEMS LTD
656146 09059 NATEL ENGINEERING COMPANY, INC. DBA POWERCUBE
656146 3B150 RAYTHEON TECHNICAL SERVICES COMPANY LLC
656146 4U884 RAYTHEON COMPANY DBA RAYTHEON
656146 82577 RAYTHEON COMPANY DBA RAYTHEON

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5962-01-284-0276

Technical Data | NSN 5962-01-284-0276

Characteristic Specifications
DESIGN FUNCTION AND QUANTITY 1 AMPLIFIER, PREAMPLIFIER
TERMINAL TYPE AND QUANTITY 38 FLAT LEADS
INCLOSURE CONFIGURATION FLAT PACK
PART NAME ASSIGNED BY CONTROLLING AGENCY MOTOR DRIVE PREAMPLIFIER
BODY LENGTH 2.010 INCHES MINIMUM AND 2.060 INCHES MAXIMUM
BODY HEIGHT 0.275 INCHES MAXIMUM
BODY WIDTH 1.112 INCHES MINIMUM AND 1.148 INCHES MAXIMUM
FEATURES PROVIDED ELECTROSTATIC SENSITIVE
SPECIAL FEATURES SOURCE CONTROL DRAWING
CRITICALITY CODE JUSTIFICATION FEAT
III END ITEM IDENTIFICATION AIRCRAFT, HORNET F/A-18; AIRCRAFT, HARRIER AV-8B; VELOCITY POOL REPARABLE PIECE PARTS
MANUFACTURERS CODE 4U884
MFR SOURCE CONTROLLING REFERENCE 656146

Restrictions/Controls & Freight Information | NSN 5962-01-284-0276

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Electro-static Discharge Susceptible:DBoth ESD and EMI sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:YThe item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 72D unknown
Originating Activity Code KE Naval ICP
Philadelphia, PA 19111
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo 3 Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

Management | NSN 5962-01-284-0276

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Special Material Content2 Electrostatic Discharge (ESD)/Electromagnetic (EM) Sensitive Item
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each