Product Details | DIGITAL MICROCIRCUIT

5962-01-312-2322 A microcircuit specifically designed to generate, modify, or process electrical signals which operate with two distinct or binary states. These states are commonly referred to as on and off, true and false, high and low, or "1" and "0".

Part Alternates: CY214945DMB, CY2149-45DMB, CY2149-45DMB ZZ , CY214945DMBZZ, 226/693, 226693, 5962-01-312-2322, 01-312-2322, 5962013122322, 013122322

Electrical and Electronic Equipment Components | Microcircuits, Electronic

Supply Group (FSG) NSN Assign. NIIN
59 12 DEC 1989 01-312-2322

Cross Reference | NSN 5962-01-312-2322

Part Number Cage Code Manufacturer
226/693 K0668 SELEX ES LTD DBA SELEX S & A S
226/693 K5728 G E C MARCONI AVIONICS LTD
CY2149-45DMB ZZ 65786 CYPRESS SEMICONDUCTOR CORPORATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5962-01-312-2322

Technical Data | NSN 5962-01-312-2322

Characteristic Specifications
OUTPUT LOGIC FORM COMPLEMENTARY-METAL OXIDE-SEMICONDUCTOR LOGIC
OPERATING TEMP RANGE -55.0 TO 125.0 DEG CELSIUS
INCLOSURE CONFIGURATION DUAL-IN-LINE
INCLOSURE MATERIAL CERAMIC
BODY LENGTH 0.875 INCHES MINIMUM AND 0.905 INCHES MAXIMUM
BODY HEIGHT 0.140 INCHES MINIMUM AND 0.175 INCHES MAXIMUM
BODY WIDTH 0.245 INCHES MINIMUM AND 0.310 INCHES MAXIMUM
FEATURES PROVIDED HIGH RELIABILITY AND BURN IN, MIL-STD-883, CLASS C AND STATIC OPERATION AND HIGH PERFORMANCE AND 3-STATE OUTPUT

Restrictions/Controls & Freight Information | NSN 5962-01-312-2322

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information