Product Details | LINEAR MICROCIRCUIT

5962-01-312-8456 A microcircuit whose output is a function of the input; that is, the output varies in a predetermined and essentially predictable manner from the input signal.

Part Alternates: TLC555MJG/883B, TLC555MJG883B, 288904135889, 28890-4135-889, 445/4/14359/000, 445414359000, 50100239, 5962-01-312-8456, 01-312-8456, 5962013128456, 013128456

Electrical and Electronic Equipment Components | Microcircuits, Electronic

Supply Group (FSG) NSN Assign. NIIN
59 22 DEC 1989 01-312-8456

Cross Reference | NSN 5962-01-312-8456

Part Number Cage Code Manufacturer
28890-4135-889 K0663 FERRANTI TECHNOLOGIES LTD
28890-4135-889 K8084 FERRANTI INTERNATIONAL PLC
445/4/14359/000 K3902 BAE SYSTEMS MARITIME SERVICES
445/4/14359/000 U4290 G E C MARCONI S3I LTD COMBAT SYSTEMS IVISION
50100239 K0233 THALES OPTRONICS LIMITED
TLC555MJG/883B 01295 TEXAS INSTRUMENTS INCORPORATED DBA TEXAS INSTRUMENTS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5962-01-312-8456

Technical Data | NSN 5962-01-312-8456

Characteristic Specifications
DESIGN FUNCTION AND QUANTITY 1 TIMER
INPUT CIRCUIT PATTERN 3 INPUT
OPERATING TEMP RANGE -55.0 TO 125.0 DEG CELSIUS
TERMINAL SURFACE TREATMENT SOLDER
INCLOSURE CONFIGURATION DUAL-IN-LINE
INCLOSURE MATERIAL CERAMIC
BODY LENGTH 0.355 INCHES MINIMUM AND 0.400 INCHES MAXIMUM
BODY HEIGHT 0.180 INCHES MINIMUM
BODY WIDTH 0.245 INCHES MINIMUM AND 0.280 INCHES MAXIMUM
FEATURES PROVIDED MONOLITHIC AND BURN IN, MIL-STD-883, CLASS B

Restrictions/Controls & Freight Information | NSN 5962-01-312-8456

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information