Product Details | DIGITAL MICROCIRCUIT

5962-01-372-7418 A microcircuit specifically designed to generate, modify, or process electrical signals which operate with two distinct or binary states. These states are commonly referred to as on and off, true and false, high and low, or "1" and "0".

Part Alternates: SNJ54ALS00AJ, G3716201, G371620-1, 5962-01-372-7418, 01-372-7418, 5962013727418, 013727418

Electrical and Electronic Equipment Components | Microcircuits, Electronic

Supply Group (FSG) NSN Assign. NIIN
59 17 MAR 1993 01-372-7418

Cross Reference | NSN 5962-01-372-7418

Part Number Cage Code Manufacturer
G371620-1 3B150 RAYTHEON TECHNICAL SERVICES COMPANY LLC
G371620-1 49956 RAYTHEON COMPANY DBA RAYTHEON
SNJ54ALS00AJ 01295 TEXAS INSTRUMENTS INCORPORATED DBA TEXAS INSTRUMENTS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5962-01-372-7418

Technical Data | NSN 5962-01-372-7418

Characteristic Specifications
OUTPUT LOGIC FORM TRANSISTOR-TRANSISTOR LOGIC
DESIGN FUNCTION AND QUANTITY 4 GATE, NAND
INPUT CIRCUIT PATTERN QUAD 2 INPUT
VOLTAGE RATING AND TYPE PER CHARACTERISTIC 4.5 VOLTS MINIMUM TOTAL SUPPLY AND 5.5 VOLTS MAXIMUM TOTAL SUPPLY
CURRENT RATING PER CHARACTERISTIC 15.00 MILLIAMPERES MINIMUM OUTPUT AND 110.00 MILLIAMPERES MAXIMUM OUTPUT
TIME RATING PER CHACTERISTIC 3.00 NANOSECONDS MINIMUM PROPAGATION DELAY TIME, LOW TO HIGH LEVEL OUTPUT AND 14.00 NANOSECONDS MAXIMUM PROPAGATION DELAY TIME, LOW TO HIGH LEVEL OUTPUT
OPERATING TEMP RANGE -55.0 TO 125.0 DEG CELSIUS
TERMINAL TYPE AND QUANTITY 14 PRINTED CIRCUIT
TERMINAL SURFACE TREATMENT SOLDER
INCLOSURE CONFIGURATION DUAL-IN-LINE
INCLOSURE MATERIAL CERAMIC
CASE OUTLINE SOURCE AND DESIGNATOR D-1 MIL-M-38510
PART NAME ASSIGNED BY CONTROLLING AGENCY MICROCIRCUIT,DIGITAL,NAND GATE,QUAD,2 INPUT
BODY LENGTH 0.765 INCHES MINIMUM AND 0.785 INCHES MAXIMUM
BODY HEIGHT 0.180 INCHES MINIMUM AND 0.200 INCHES MAXIMUM
BODY WIDTH 0.290 INCHES MINIMUM AND 0.310 INCHES MAXIMUM
MAXIMUM POWER DISSIPATION RATING 16.4 MILLIWATTS
STORAGE TEMP RANGE -65.0 TO 150.0 DEG CELSIUS
FEATURES PROVIDED BURN IN, MIL-STD-883, CLASS B AND ELECTROSTATIC SENSITIVE AND HERMETICALLY SEALED AND RADIATION HARDENED AND SCHOTTKY AND MONOLITHIC AND 2-STATE OUTPUT AND LOW POWER AND TESTED TO MIL-STD-883
SPECIAL FEATURES HCI;ESD,HERMATICALLY SEALED
TEST DATA DOCUMENT 96906-MIL-STD-883 STANDARD
SPECIFICATION/STANDARD DATA 81349-MIL-M-38510/370 GOVERNMENT SPECIFICATION
CRITICALITY CODE JUSTIFICATION FEAT
MANUFACTURERS CODE 3B150
MFR SOURCE CONTROLLING REFERENCE G371620-1

Restrictions/Controls & Freight Information | NSN 5962-01-372-7418

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Electro-static Discharge Susceptible:BESD sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:M The item is specifically designed to be or selected as being nuclear hard. In addition the item has other critical features such as tolerance, fit restrictions or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating
Less than truck load rating J 100.2
Water commodity Code 72D unknown
Originating Activity Code TA Sacramento Air Logistics Center
McClellan AFB, CA 95652-5609
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Q Extremely fragile items including delicate instruments.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo 3 Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

Management | NSN 5962-01-372-7418

Category Code Description
Materiel Management Aggregation CodeMZSU:MILSTAR
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplyFGZOgden Air Logistics Center
Hill AFB, UT 84056-5609
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesDDoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes9INavy-owned stocks of consumable material managed by the Air Force within the Odgen Air Logistics Center
Naval Inventory Control Point, Mechanicsburg
Source of SupplyFGZOgden Air Logistics Center
Hill AFB, UT 84056-5609
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesDDoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each