Product Details | DIGITAL MICROCIRCUIT

5962-01-492-5495 A microcircuit specifically designed to generate, modify, or process electrical signals which operate with two distinct or binary states. These states are commonly referred to as on and off, true and false, high and low, or "1" and "0".

Part Alternates: CD54HC541F/3A, CD54HC541F3A, 5962-01-492-5495, 01-492-5495, 5962014925495, 014925495

Electrical and Electronic Equipment Components | Microcircuits, Electronic

Supply Group (FSG) NSN Assign. NIIN
59 03 DEC 2001 01-492-5495

Cross Reference | NSN 5962-01-492-5495

Part Number Cage Code Manufacturer
CD54HC541F/3A 1MY79 INTERSIL COMMUNICATIONS INC.
CD54HC541F/3A 34371 INTERSIL CORPORATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5962-01-492-5495

Technical Data | NSN 5962-01-492-5495

Characteristic Specifications
OUTPUT LOGIC FORM COMPLEMENTARY-METAL OXIDE-SEMICONDUCTOR LOGIC
DESIGN FUNCTION AND QUANTITY 8 DRIVER, BUS
INPUT CIRCUIT PATTERN 10 INPUT
VOLTAGE RATING AND TYPE PER CHARACTERISTIC -0.5 VOLTS MINIMUM POWER SOURCE AND 7.0 VOLTS MAXIMUM POWER SOURCE
OPERATING TEMP RANGE -55.0 TO 125.0 DEG CELSIUS
TERMINAL TYPE AND QUANTITY 20 PRINTED CIRCUIT
TERMINAL SURFACE TREATMENT SOLDER
INCLOSURE CONFIGURATION DUAL-IN-LINE
INCLOSURE MATERIAL CERAMIC
CASE OUTLINE SOURCE AND DESIGNATOR D-8 MIL-M-38510
BODY LENGTH 1.060 INCHES MAXIMUM
BODY HEIGHT 0.130 INCHES MINIMUM AND 0.185 INCHES MAXIMUM
BODY WIDTH 0.220 INCHES MINIMUM AND 0.310 INCHES MAXIMUM
MAXIMUM POWER DISSIPATION RATING 300.0 MILLIWATTS
STORAGE TEMP RANGE -65.0 TO 150.0 DEG CELSIUS
FEATURES PROVIDED HERMETICALLY SEALED AND BURN IN AND 3-STATE OUTPUT AND HIGH SPEED
III UNPACKAGED UNIT WEIGHT 2.4 GRAMS

Restrictions/Controls & Freight Information | NSN 5962-01-492-5495

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information