Product Details | LINEAR MICROCIRCUIT

5962-01-500-7528 A microcircuit whose output is a function of the input; that is, the output varies in a predetermined and essentially predictable manner from the input signal.

Part Alternates: 59629092501MCX, 5962-9092501MCX, 5962-01-500-7528, 01-500-7528, 5962015007528, 015007528

Electrical and Electronic Equipment Components | Microcircuits, Electronic

Supply Group (FSG) NSN Assign. NIIN
59 09 SEP 2002 01-500-7528

Cross Reference | NSN 5962-01-500-7528

Part Number Cage Code Manufacturer
5962-9092501MCX 16236 DLA LAND AND MARITIME
5962-9092501MCX 67268 DLA LAND AND MARITIME OPNS SUPPORT GROUP

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5962-01-500-7528

Technical Data | NSN 5962-01-500-7528

Characteristic Specifications
DESIGN FUNCTION AND QUANTITY 1 AMPLIFIER, OPERATIONAL, GENERAL PURPOSE
VOLTAGE RATING AND TYPE PER CHARACTERISTIC -7.0 VOLTS MINIMUM TOTAL SUPPLY AND 7.0 VOLTS MAXIMUM TOTAL SUPPLY
CURRENT RATING PER CHARACTERISTIC 70.00 MILLIAMPERES NOMINAL OUTPUT
OPERATING TEMP RANGE -55.0 TO 125.0 DEG CELSIUS
TERMINAL TYPE AND QUANTITY 14 PIN
INCLOSURE CONFIGURATION DUAL-IN-LINE
INCLOSURE MATERIAL SILICON
CASE OUTLINE SOURCE AND DESIGNATOR D-1 MIL-M-38510
BODY LENGTH 0.785 INCHES NOMINAL
BODY HEIGHT 0.200 INCHES NOMINAL
BODY WIDTH 0.310 INCHES NOMINAL
STORAGE TEMP RANGE -65.0 TO 150.0 DEG CELSIUS
MANUFACTURERS CODE 67268
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE 5962-9092501MCX

Restrictions/Controls & Freight Information | NSN 5962-01-500-7528

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information