Product Details | DIGITAL MICROCIRCUIT

5962-01-515-8441 A microcircuit specifically designed to generate, modify, or process electrical signals which operate with two distinct or binary states. These states are commonly referred to as on and off, true and false, high and low, or "1" and "0".

Part Alternates: MAX4503EUK, 5962-01-515-8441, 01-515-8441, 5962015158441, 015158441

Electrical and Electronic Equipment Components | Microcircuits, Electronic

Supply Group (FSG) NSN Assign. NIIN
59 10 DEC 2003 01-515-8441

Cross Reference | NSN 5962-01-515-8441

Part Number Cage Code Manufacturer
MAX4503EUK 1ES66 MAXIM INTEGRATED PRODUCTS, INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5962-01-515-8441

Technical Data | NSN 5962-01-515-8441

Characteristic Specifications
OUTPUT LOGIC FORM COMPLEMENTARY-METAL OXIDE-SEMICONDUCTOR LOGIC
DESIGN FUNCTION AND QUANTITY 1 DRIVER, LAMP
VOLTAGE RATING AND TYPE PER CHARACTERISTIC 1.0 VOLTS MINIMUM POWER SOURCE AND 6.0 VOLTS MAXIMUM POWER SOURCE
OPERATING TEMP RANGE -40.0 TO 85.0 DEG CELSIUS
TERMINAL TYPE AND QUANTITY 5 GULLWING
PART NAME ASSIGNED BY CONTROLLING AGENCY CMOS ANALOG SWITCH
BODY LENGTH 2.80 MILLIMETERS MINIMUM AND 3.00 MILLIMETERS MAXIMUM
BODY HEIGHT 0.90 MILLIMETERS MINIMUM AND 1.45 MILLIMETERS MAXIMUM
STORAGE TEMP RANGE -65.0 TO 150.0 DEG CELSIUS
FEATURES PROVIDED LOW VOLTAGE
SPECIAL FEATURES CONTINUOUS POWER DISSIPATION RATING 727 MW
III OVERALL WIDTH 2.60 MILLIMETERS MINIMUM AND 3.00 MILLIMETERS MAXIMUM

Restrictions/Controls & Freight Information | NSN 5962-01-515-8441

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information