Product Details | HYBRID MICROCIRCUIT

5962-01-517-8633 A circuit in which one type of microcircuit is combined with some other type of microcircuit or with discrete components. For two microcircuits on a common mounting or on each other, see MICROCIRCUIT ASSEMBLY. For microcircuits having a complete independent memory function, see MICROCIRCUIT (1), MEMORY.

Part Alternates: 756, 5962-01-517-8633, 01-517-8633, 5962015178633, 015178633

Electrical and Electronic Equipment Components | Microcircuits, Electronic

Supply Group (FSG) NSN Assign. NIIN
59 23 FEB 2004 01-517-8633

Cross Reference | NSN 5962-01-517-8633

Part Number Cage Code Manufacturer
756 61651 ANALOG MODULES, INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5962-01-517-8633

Technical Data | NSN 5962-01-517-8633

Characteristic Specifications
OUTPUT LOGIC FORM TRANSISTOR COUPLED LOGIC AND COMPLEMENTARY-METAL OXIDE-SEMICONDUCTOR LOGIC
DESIGN FUNCTION AND QUANTITY 1 RECEIVER
VOLTAGE RATING AND TYPE PER CHARACTERISTIC 12.0 VOLTS NOMINAL POWER SOURCE
CURRENT RATING PER CHARACTERISTIC 35.00 MILLIAMPERES NOMINAL SUPPLY
OPERATING TEMP RANGE -32.0 TO 64.0 DEG CELSIUS
INCLOSURE CONFIGURATION CAN
INCLOSURE MATERIAL SILICON
PART NAME ASSIGNED BY CONTROLLING AGENCY HYBRID LASER RANGEFINDER RECEIVER
BODY LENGTH 0.300 INCHES NOMINAL
BODY OUTSIDE DIAMETER 0.600 INCHES NOMINAL
BODY HEIGHT 0.425 INCHES NOMINAL
STORAGE TEMP RANGE -55.0 TO 125.0 DEG CELSIUS
FEATURES PROVIDED HIGH SENSITIVITY

Restrictions/Controls & Freight Information | NSN 5962-01-517-8633

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information