NSN 5962-01-519-4999 UC3610N, 01-519-4999, 015194999
Product Details | LINEAR MICROCIRCUIT
5962-01-519-4999 A microcircuit whose output is a function of the input; that is, the output varies in a predetermined and essentially predictable manner from the input signal.
Part Alternates: UC3610N, 5962-01-519-4999, 01-519-4999, 5962015194999, 015194999
Electrical and Electronic Equipment Components | Microcircuits, Electronic
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 21 APR 2004 | 01-519-4999 | 31778 ( MICROCIRCUIT, LINEAR ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5962-01-519-4999
Related Products | NSN 5962-01-519-4999
Technical Data | NSN 5962-01-519-4999
| Characteristic | Specifications |
|---|---|
| VOLTAGE RATING AND TYPE PER CHARACTERISTIC | 50.0 VOLTS MAXIMUM INVERSE |
| CURRENT RATING PER CHARACTERISTIC | 3.00 AMPERES NOMINAL OUTPUT |
| TIME RATING PER CHACTERISTIC | 15.00 NANOSECONDS NOMINAL REVERSE RECOVERY |
| OPERATING TEMP RANGE | 0.0 TO 70.0 DEG CELSIUS |
| TERMINAL TYPE AND QUANTITY | 8 PIN |
| INCLOSURE MATERIAL | PLASTIC |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | DUAL SCHOTTKEY DIODE BRIDGE |
| MAXIMUM POWER DISSIPATION RATING | 1.0 WATTS |
| STORAGE TEMP RANGE | -65.0 TO 150.0 DEG CELSIUS |
| SPECIAL FEATURES | COPPER-LEADED PLASTIC PACKAGE |
| III SUPPLEMENTARY FEATURES | FUNCTIONAL DESCRIPTION DESIGNED FOR HIGH-CURRENT, LOW DUTY-CYCLE APPLICATIONS TYPICAL OF FLYBACK VOLTAGE CLAMPING FOR INDUCTIVE LOADS |
Restrictions/Controls & Freight Information | NSN 5962-01-519-4999
| Category | Code | Description |
|---|---|---|
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||