Product Details | LINEAR MICROCIRCUIT

5962-01-520-3425 A microcircuit whose output is a function of the input; that is, the output varies in a predetermined and essentially predictable manner from the input signal.

Part Alternates: UC1854J, 5962-01-520-3425, 01-520-3425, 5962015203425, 015203425

Electrical and Electronic Equipment Components | Microcircuits, Electronic

Supply Group (FSG) NSN Assign. NIIN
59 07 MAY 2004 01-520-3425

Cross Reference | NSN 5962-01-520-3425

Part Number Cage Code Manufacturer
UC1854J 48726 UNITRODE INTEGRATED CIRCUITS CORP DIV OF UNITRODE CORP

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5962-01-520-3425

Technical Data | NSN 5962-01-520-3425

Characteristic Specifications
DESIGN FUNCTION AND QUANTITY 1 REGULATOR, CURRENT
VOLTAGE RATING AND TYPE PER CHARACTERISTIC 35.0 VOLTS MAXIMUM TOTAL SUPPLY
CURRENT RATING PER CHARACTERISTIC 10.00 MILLIAMPERES MAXIMUM INPUT
OPERATING TEMP RANGE -55.0 TO 125.0 DEG CELSIUS
TERMINAL TYPE AND QUANTITY 16 PRINTED CIRCUIT
INCLOSURE CONFIGURATION DUAL-IN-LINE
INCLOSURE MATERIAL CERAMIC
PART NAME ASSIGNED BY CONTROLLING AGENCY HIGH POWER FACTOR PREREGULATOR
BODY LENGTH 0.840 INCHES MAXIMUM
BODY HEIGHT 0.140 INCHES MINIMUM AND 0.185 INCHES MAXIMUM
BODY WIDTH 0.245 INCHES MINIMUM AND 0.300 INCHES MAXIMUM
MAXIMUM POWER DISSIPATION RATING 1.000 WATTS
STORAGE TEMP RANGE -65.0 TO 150.0 DEG CELSIUS
FEATURES PROVIDED LOW NOISE

Restrictions/Controls & Freight Information | NSN 5962-01-520-3425

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information