Product Details | WASHER INSULATOR

5970-01-179-3753 An insulator that is essentially thin and flat, with one through hole centrally located. The general shape may vary by the addition of features such as beveled edges, indented surfaces, through hole keys, and/or peripheral flats. The thickness measured between the two parallel bearing surfaces must not exceed 25 percent of the outside diameter or the shortest distance between peripheral flats. The thickness measured between the two parallel bearing surfaces must not exceed 25 percent of the outside diameter or the shortest distance between peripheral flats. Excludes items with more than one hole. See also INSULATOR, DISK; INSULATOR, BEAD; INSULATOR, BUSHING; and INSULATOR, PLATE

Part Alternates: 6231640001, 623-1640-001, 5970-01-179-3753, 01-179-3753, 5970011793753, 011793753

Electrical and Electronic Equipment Components | Electrical Insulators and Insulating Materials

Supply Group (FSG) NSN Assign. NIIN
59 17 MAY 1984 01-179-3753

Drawings & Photos | NSN 5970-01-179-3753


Cross Reference | NSN 5970-01-179-3753

Part Number Cage Code Manufacturer
623-1640-001 13499 ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5970-01-179-3753

Technical Data | NSN 5970-01-179-3753

Characteristic Specifications
STYLE DESIGNATOR Q1 ROUND, FLAT
INSIDE DIAMETER 0.370 INCHES NOMINAL
OUTSIDE DIAMETER 1.160 INCHES NOMINAL
OVERALL HEIGHT 0.010 INCHES NOMINAL
MATERIAL AND LOCATION OVERALL PLASTIC, LAMINATED
MANUFACTURERS CODE 13499
DESIGN CONTROL REFERENCE 623-1640-001

Restrictions/Controls & Freight Information | NSN 5970-01-179-3753

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 103300 INSULATING MATERIAL NOI
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 72D unknown
Originating Activity Code TG Warner-Robins Air Logistics Center
Robins AFB, GA 31098-5609
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable