Product Details | ELECTRICAL INSULATION SLEEVING

5970-01-269-7928 A rigid or flexible tubing having uniform inside and outside diameters in the overall length. It is specifically designed to prevent any undesirable flow of current between conductors and other objects. Includes shrinkable type tubing, items in bulk and in specific fabricated lengths (cut to size). Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (as modified); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; and TUBING, NONMETALLIC.

Part Alternates: RNF100 1-4-1200 CLEAR, RNF100141200CLEAR, RNF100TYPE2-1/4INCLEAR, RNF100TYPE214INCLEAR, 5970-01-269-7928, 01-269-7928, 5970012697928, 012697928

Electrical and Electronic Equipment Components | Electrical Insulators and Insulating Materials

Supply Group (FSG) NSN Assign. NIIN
59 22 DEC 1987 01-269-7928

Drawings & Photos | NSN 5970-01-269-7928


Cross Reference | NSN 5970-01-269-7928

Part Number Cage Code Manufacturer
RNF100 1-4-1200 CLEAR 06090 TYCO ELECTRONICS CORPORATION
RNF100TYPE2-1/4INCLEAR 06090 TYCO ELECTRONICS CORPORATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5970-01-269-7928

Technical Data | NSN 5970-01-269-7928

Characteristic Specifications
STYLE DESIGNATOR A1 SHRINKABLE
OVERALL LENGTH 4.000 FEET NOMINAL
EXPANDED INSIDE DIAMETER 6.4 MILLIMETERS NOMINAL
RECOVERED INSIDE DIAMETER 3.2 MILLIMETERS NOMINAL
RECOVERED WALL THICKNESS 0.64 MILLIMETERS NOMINAL
MATERIAL PLASTIC, POLYOLEFIN, MIL-I-23053/5, CLASS 2
COLOR CLEAR
FLEXIBILITY FLEXIBLE
HEAT SHRINKAGE RATING IN PERCENT 50.0
TEMP RATING -55.0 DEG CELSIUS AND 135.0 DEG CELSIUS
MINIMUM TENSILE STRENGTH 1800 POUNDS PER SQUARE INCH
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS 1000.0 VOLTS PER MIL /0.001 INCH/
ENVIRONMENTAL PROTECTION CORROSION RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT
RELIABILITY INDICATOR NOT ESTABLISHED

Restrictions/Controls & Freight Information | NSN 5970-01-269-7928

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information