Product Details | ELECTRICAL EQUIPMENT CABINET

5975-01-357-7838 An enclosure generally fabricated of sheet material designed to accommodate (but does not include) electrical/electronic equipment so that the equipment may be operated without removal. It may include wires, cables, terminal boards, connectors, etc., required for equipment operation. For items designed to accommodate equipment mounted on panels, see RACK, ELECTRICAL EQUIPMENT. See also CASE (2) (as modified). Excludes INTERCONNECTING BOX; INTERCONNECTING CABINET; JUNCTION BOX; and TERMINAL BOX.

Part Alternates: S17506C, S17506-C, 5975-01-357-7838, 01-357-7838, 5975013577838, 013577838

Electrical and Electronic Equipment Components | Electrical Hardware and Supplies

Supply Group (FSG) NSN Assign. NIIN
59 30 APR 1992 01-357-7838

Drawings & Photos | NSN 5975-01-357-7838


Cross Reference | NSN 5975-01-357-7838

Part Number Cage Code Manufacturer
S17506-C 98587 IMS ENGINEERED PRODUCTS, LLC DBA AMCO ENGINEERING CO

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5975-01-357-7838

Technical Data | NSN 5975-01-357-7838

Characteristic Specifications
STYLE DESIGNATOR B1 UTILITY W/REMOVABLE FRONT AND BACK
OVERALL DEPTH 13.500 INCHES NOMINAL
OVERALL HEIGHT 78.560 INCHES NOMINAL
OVERALL WIDTH 23.310 INCHES NOMINAL
PANEL SPACE HEIGHT 56.250 INCHES NOMINAL
MATERIAL ALUMINUM

Restrictions/Controls & Freight Information | NSN 5975-01-357-7838

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061110 ELECTRICAL:CABINET,FRAMES
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 72D unknown
Originating Activity Code SE San Antonio Air Logistics Center
Kelly AFB, TX 78241-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable