Product Details | ELECTRICAL-ELECTRONIC EQUIPMENT CHASSIS

5975-01-492-9830 A box, frame, or plate fabricated of electrically conductive material designed to mount, but which does not include, electronic components and their associated circuitry. It may have facilities for attachment to a rack or cabinet or to accommodate specially designed components. It may include a shielding function, integral wiring, and mounting hardware as part of the item. Excludes MOUNTING BASE, ELECTRICAL EQUIPMENT.

Part Alternates: 1582AS1871, 1582AS187-1, 5975-01-492-9830, 01-492-9830, 5975014929830, 014929830

Electrical and Electronic Equipment Components | Electrical Hardware and Supplies

Supply Group (FSG) NSN Assign. NIIN
59 18 DEC 2001 01-492-9830

Drawings & Photos | NSN 5975-01-492-9830


Cross Reference | NSN 5975-01-492-9830

Part Number Cage Code Manufacturer
1582AS187-1 30003 NAVAL AIR SYSTEMS COMMAND

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5975-01-492-9830

Technical Data | NSN 5975-01-492-9830

Characteristic Specifications
STYLE DESIGNATOR C7 CLOSED ENDS AND SIDES FLANGED
OVERALL DEPTH 5.120 INCHES NOMINAL
OVERALL HEIGHT ANY ACCEPTABLE
OVERALL WIDTH 6.250 INCHES NOMINAL
MATERIAL THICKNESS 0.690 INCHES NOMINAL
MATERIAL ALUMINUM
DESIGN FEATURE PUNCHED HOLES
MOUNTING HOLE DIAMETER 0.156 INCHES
MOUNTING HOLE QUANTITY 4
CENTER TO CENTER DISTANCE BETWEEN MOUNTING HOLES ALONG WIDTH 2.312 INCHES
III PART NAME ASSIGNED BY CONTROLLING AGENCY FRAME, METER

Restrictions/Controls & Freight Information | NSN 5975-01-492-9830

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information