Product Details | ELECTRICAL-ELECTRONIC EQUIPMENT CHASSIS

5975-01-606-1558 A box, frame, or plate fabricated of electrically conductive material designed to mount, but which does not include, electronic components and their associated circuitry. It may have facilities for attachment to a rack or cabinet or to accommodate specially designed components. It may include a shielding function, integral wiring, and mounting hardware as part of the item. Excludes MOUNTING BASE, ELECTRICAL EQUIPMENT.

Part Alternates: 110330, 11-0330 , 5975-01-606-1558, 01-606-1558, 5975016061558, 016061558

Electrical and Electronic Equipment Components | Electrical Hardware and Supplies

Supply Group (FSG) NSN Assign. NIIN
59 2012130 01-606-1558

Cross Reference | NSN 5975-01-606-1558

Part Number Cage Code Manufacturer
11-0330 3GNA5 PDE TECHNOLOGY CORPORATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5975-01-606-1558

Technical Data | NSN 5975-01-606-1558

Characteristic Specifications
STYLE DESIGNATOR CLOSED ENDS AND SIDES W/BOTTOM PLATE
OVERALL DEPTH 17.000 INCHES NOMINAL
OVERALL HEIGHT 3.500 INCHES NOMINAL
OVERALL WIDTH 23.250 INCHES NOMINAL
MATERIAL STEEL
DESIGN FEATURE BLANK
SPECIAL FEATURES WITH LOCKING DOOR;PSU WATTS:200.0;DC FAN DIM:80X80X25;CFM:35,39;FAN QUANTITY:1
III PART NAME ASSIGNED BY CONTROLLING AGENCY 2U 2 FH 5.25 INCH BAY SCSI RM ENCL

Restrictions/Controls & Freight Information | NSN 5975-01-606-1558

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information