NSN 5980-01-188-4346 SLH98, 914137, 244227
Product Details | LIGHT EMITTING DIODE
5980-01-188-4346 A two electrode, solid state, optoelectronic device that emits visible or infrared radiant energy when electrically energized. May or may not include mounting hardware and/or heat sink. Excludes LAMP, CARTRIDGE; and LIGHT, INDICATOR. For solid state devices which are responsive to infrared or radiant energy, see SEMICONDUCTOR DEVICE (1), PHOTO.20259800046Optoelectronic Devices and Associated Hardware62100045Indoor and Outdoor Electric Lighting Fixtures
Part Alternates: SLH98, 914137, 244227, 5980-01-188-4346, 01-188-4346, 5980011884346, 011884346
Electrical and Electronic Equipment Components | Optoelectronic Devices and Associated Hardware
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 05 SEP 1984 | 01-188-4346 | 32371 ( LIGHT EMITTING DIODE ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5980-01-188-4346
Related Products | NSN 5980-01-188-4346
Technical Data | NSN 5980-01-188-4346
| Characteristic | Specifications |
|---|---|
| INTERNAL CONFIGURATION | POINT CONTACT |
| INTERNAL JUNCTION CONFIGURATION | PINIP |
| VOLTAGE RATING IN VOLTS PER CHARACTERISTIC | 2.0 MAXIMUM REVERSE VOLTAGE, DC |
| CURRENT RATING PER CHARACTERISTIC | 300.00 MILLIAMPERES MAXIMUM FORWARD CURRENT, DC |
| POWER RATING PER CHARACTERISTIC | 25.0 MILLIWATTS NOMINAL TOTAL POWER DISSIPATION |
| MAXIMUM OPERATING TEMP PER MEASUREMENT POINT | 125.0 DEG CELSIUS AMBIENT AIR |
| INCLOSURE MATERIAL | GLASS AND METAL |
| MOUNTING METHOD | THREADED STUD |
| MOUNTING FACILITY QUANTITY | 1 |
| THREAD SERIES DESIGNATOR | UNC |
| NOMINAL THREAD SIZE | 0.138 INCHES |
| TERMINAL TYPE AND QUANTITY | 1 TAB, SOLDER LUG AND 1 THREADED STUD |
| OVERALL LENGTH | 0.707 INCHES MAXIMUM |
| OVERALL DIAMETER | 0.575 INCHES NOMINAL |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE |
| SPECIAL FEATURES | ENCAPSULATED IN FERRULE |
Restrictions/Controls & Freight Information | NSN 5980-01-188-4346
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | Q | Strategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.” |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 063025 | SEMICONDUCTORS/DEVICES NOI ETC |
| Less than car load rating | ||
| Less than truck load rating | W | Rating Variable |
| Water commodity Code | 658 | unknown |
| Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5980-01-188-4346
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |