Product Details | DIRECTIONAL COUPLER

5985-00-053-0229 An item specifically designed to be inserted into a transmission line, waveguide or coaxial transmission line to provide a suitable test outlet. The test signal is attenuated to a predetermined value.

Part Alternates: 711D608G1, 5985-00-053-0229, 00-053-0229, 5985000530229, 000530229

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 17 NOV 1967 00-053-0229

Cross Reference | NSN 5985-00-053-0229

Part Number Cage Code Manufacturer
711D608G1 99971 LOCKHEED MARTIN CORP NAVAL ELECTRONICS & SURVEILLANCE

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-00-053-0229

Technical Data | NSN 5985-00-053-0229

Characteristic Specifications
UNIT TYPE COAXIAL LINE OR TRANSMISSION LINE
RADIO FREQUENCY RATING NOT RATED
DESIGN TYPE BIDIRECTIONAL
POWER LOSS IN DECIBELS NOT RATED
TERMINAL FITTING NAME ELECTRICAL CONNECTOR
TERMINAL FITTING CONTROLLING AGENCY GENERAL ELECTRIC COMPANY
TERMINAL FITTING IDENTIFYING NUMBER PART NO.885C706P1 AND 885C709P1
TERMINAL FITTING USAGE DESIGN MAIN LINE AND SECONDARY LINE
OVERALL LENGTH 3.620 INCHES NOMINAL
OVERALL WIDTH 2.500 INCHES NOMINAL
OVERALL HEIGHT 1.630 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 5985-00-053-0229

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 658 unknown
Originating Activity Code TG Warner-Robins Air Logistics Center
Robins AFB, GA 31098-5609
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable