Product Details | DIRECTIONAL COUPLER

5985-00-924-9076 An item specifically designed to be inserted into a transmission line, waveguide or coaxial transmission line to provide a suitable test outlet. The test signal is attenuated to a predetermined value.

Part Alternates: 5199022, 519902-2, 5985-00-924-9076, 00-924-9076, 5985009249076, 009249076

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 14 JAN 1966 00-924-9076

Cross Reference | NSN 5985-00-924-9076

Part Number Cage Code Manufacturer
519902-2 96214 RAYTHEON COMPANY DBA RAYTHEON

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-00-924-9076

Technical Data | NSN 5985-00-924-9076

Characteristic Specifications
UNIT TYPE WAVEGUIDE
RADIO FREQUENCY RATING 16.6 GIGAHERTZ MINIMUM AND 17.1 GIGAHERTZ MAXIMUM
VOLTAGE STANDING WAVE RATIO AT REFERENCE FREQUENCY 1.1 TO 1 AT 17.1 GHZ
DESIGN TYPE BIDIRECTIONAL
POWER LOSS IN DECIBELS 25.0
TERMINAL FITTING NAME FLANGE,WAVEGUIDE,CHOKE; FLANGE,WAVEGUIDE,COVER
TERMINAL FITTING CONTROLLING AGENCY TEXAS INSTRUMENTS INC APPARATUS DIVISON; TEXAS INSTRUMENTS INC APPARATUS DIVISION
TERMINAL FITTING IDENTIFYING NUMBER PART NO. 416735-1; PART NO. 416736-1
TERMINAL FITTING USAGE DESIGN MAIN LINE AND MAIN LINE
OVERALL LENGTH 6.946 INCHES NOMINAL
OVERALL WIDTH 1.320 INCHES NOMINAL
OVERALL HEIGHT 5.000 INCHES NOMINAL
MANUFACTURERS CODE 96214
DESIGN CONTROL REFERENCE 519902-2

Restrictions/Controls & Freight Information | NSN 5985-00-924-9076

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating P 77.5
Less than truck load rating W Rating Variable
Water commodity Code 72D unknown
Originating Activity Code TG Warner-Robins Air Logistics Center
Robins AFB, GA 31098-5609
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code Z unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable