NSN 5985-01-197-0548 A2916205A, A2916-20-5A, DCS2126
Product Details | DIRECTIONAL COUPLER
5985-01-197-0548 An item specifically designed to be inserted into a transmission line, waveguide or coaxial transmission line to provide a suitable test outlet. The test signal is attenuated to a predetermined value.
Part Alternates: A2916205A, A2916-20-5A, DCS2126, DCS212-6, 52.2813.715.15LV, 52281371515LV, 5985-01-197-0548, 01-197-0548, 5985011970548, 011970548
Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 18 DEC 1984 | 01-197-0548 | 00384 ( COUPLER, DIRECTIONAL ) |
Cross Reference | NSN 5985-01-197-0548
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 52.2813.715.15LV | D1901 | AIRBUS DEFENCE AND SPACE GMBH DIV SEPS |
| A2916-20-5A | 50021 | TECHNICAL RESEARCH AND MANUFACTURING, INC. |
| A2916-20-5A | 51283 | TECHNICAL SERVICES LABORATORY, INC. DBA TSL-REICO |
| A2916-20-5A | 60590 | AIKEN ADVANCED SYSTEMS INC A DIV OF AMSTAR TECHNICAL PRODUCTS |
| DCS212-6 | 50021 | TECHNICAL RESEARCH AND MANUFACTURING, INC. |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5985-01-197-0548
Related Products | NSN 5985-01-197-0548
Technical Data | NSN 5985-01-197-0548
| Characteristic | Specifications |
|---|---|
| UNIT TYPE | COAXIAL LINE |
| RADIO FREQUENCY RATING | 12.0 GIGAHERTZ MINIMUM AND 18.0 GIGAHERTZ MAXIMUM |
| VOLTAGE STANDING WAVE RATIO AT REFERENCE FREQUENCY | 1.7 TO 1 AT 12 TO 18 GHZ |
| DESIGN TYPE | UNIDIRECTIONAL |
| POWER LOSS IN DECIBELS | 0.8 |
| TERMINAL FITTING NAME | FEMALE SMA CONNECTOR |
| TERMINAL FITTING CONTROLLING AGENCY | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY AGENCIES |
| TERMINAL FITTING IDENTIFYING NUMBER | MIL-C-39012 |
| TERMINAL FITTING USAGE DESIGN | MAIN LINE |
| OVERALL LENGTH | 1.000 INCHES NOMINAL |
| OVERALL WIDTH | 0.500 INCHES NOMINAL |
| OVERALL HEIGHT | 0.375 INCHES NOMINAL |
Restrictions/Controls & Freight Information | NSN 5985-01-197-0548
| Category | Code | Description |
|---|---|---|
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Precious Metals Indicator Code: | U | Precious metal type is unknown |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||