Product Details | FIXED ATTENUATOR

5985-01-215-2210 A device for reducing the strength of an alternating current signal by a fixed or predetermined amount, without causing appreciable signal distortion, by maintaining correct impedance match.

Part Alternates: 29011DB, 290-11DB, 5985-01-215-2210, 01-215-2210, 5985012152210, 012152210

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 22 AUG 1985 01-215-2210

Cross Reference | NSN 5985-01-215-2210

Part Number Cage Code Manufacturer
290-11DB 34078 EMERSON NETWORK POWER CONNECTIVITY SOLUTIONS, INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-01-215-2210

Technical Data | NSN 5985-01-215-2210

Characteristic Specifications
APPLICATION DESIGN TRANSMISSION LINE
INPUT IMPEDANCE RATING IN OHMS 50.0
OUTPUT IMPEDANCE RATING IN OHMS 50.0
FREQUENCY RANGE 0.000 HERTZ MINIMUM AND
VOLTAGE STANDING WAVE RATIO 1.07
RF SIGNAL ATTENUATION IN DECIBELS 11.0
ATTENUATION ACCURACY IN DECIBELS -0.50 TO 0.50
POWER RATING 2.0 WATTS AVERAGE
OPERATING TEMP RANGE -65.0 TO 125.0 DEG CELSIUS
BODY STYLE ROUND, TERMINAL/TERMINALS IN OPPOSITE SURFACE
OVERALL LENGTH 0.860 INCHES NOMINAL
OVERALL DIAMETER 0.280 INCHES NOMINAL
BODY MATERIAL STEEL, STAINLESS
BODY SURFACE TREATMENT ANY ACCEPTABLE
TERMINAL TYPE AND QUANTITY 2 CONNECTOR
COAXIAL CONNECTOR SERIES DESIGNATION SMA
CONNECTION TYPE PER FUNCTION FEMALE INPUT AND
MOUNTING METHOD CONNECTOR

Restrictions/Controls & Freight Information | NSN 5985-01-215-2210

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description