Product Details | RADIO FREQUENCY POWER DIVIDER

5985-01-409-0662 An item specifically designed to separate incoming radio frequency power into predetermined proportional values at its output terminals.20358950037Miscellaneous Communication Equipment59850043Antennas, Waveguides, and Related Equipment66250070Electrical and Electronic Properties Measuring and Testing Instruments

Part Alternates: MA509528, ES870302, ES8703-02, 5985-01-409-0662, 01-409-0662, 5985014090662, 014090662

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 03 MAR 1995 01-409-0662

Demand History | NSN 5985-01-409-0662

Part Number Request Date QTY Origin
5985-01-409-0662 2012-03-85 1 DIBBS

Cross Reference | NSN 5985-01-409-0662

Part Number Cage Code Manufacturer
ES8703-02 20418 DRS SUSTAINMENT SYSTEMS, INC. Use CAGE Code 98255 for cataloging
MA509528 00779 TYCO ELECTRONICS CORPORATION
MA509528 11556 M/A-COM INC
MA509528 20418 DRS SUSTAINMENT SYSTEMS, INC. Use CAGE Code 98255 for cataloging
MA509528 66544 CONTINENTAL MICROWAVE AND TOOL CO., INC.
MA509528 96341 COBHAM ELECTRONIC SYSTEMS INC. DBA COBHAM DEFENSE ELECTRONICS
MA509528 98255 DRS SUSTAINMENT SYSTEMS, INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-01-409-0662

Technical Data | NSN 5985-01-409-0662

Characteristic Specifications
FREQUENCY RATING 16.425 GIGAHERTZ MINIMUM AND 16.625 GIGAHERTZ MAXIMUM
OUTPUT QUANTITY 2
VOLTAGE STANDING WAVE RATIO 1.10
INSERTION LOSS IN DECIBELS 0.20
TERMINAL TYPE AND QUANTITY 1 CONNECTOR, RECEPTACLE
OVERALL LENGTH 5.340 INCHES NOMINAL
OVERALL WIDTH 2.720 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 5985-01-409-0662

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 116030 MACHINES ETC DATA PROCESSING
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 72D unknown
Originating Activity Code TH Defense Supply Center Columbus
Columbus, OH 43215
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5985-01-409-0662

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each