Product Details | RADIO FREQUENCY CIRCULATOR

5985-01-547-9640 A waveguide, stripline, or coaxial component having three or more ports (terminals), so arranged that energy entering one port is transmitted to the next adjacent port in a particular direction while decoupling the energy from all other ports. Excludes SWITCH, RADIO FREQUENCY TRANSMISSION LINE; and SWITCH, WAVEGUIDE.

Part Alternates: SM22658, GC012014DI , 5985-01-547-9640, 01-547-9640, 5985015479640, 015479640

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 05 FEB 2007 01-547-9640

Cross Reference | NSN 5985-01-547-9640

Part Number Cage Code Manufacturer
GC012014DI 384CB GIZA TECHNOLOGIES SA
SM22658 1CY63 SIERRA MICROWAVE TECHNOLOGY LLC DBA S M T

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-01-547-9640

Technical Data | NSN 5985-01-547-9640

Characteristic Specifications
FREQUENCY RANGE RATING 1.2 TO 1.4 GIGAHERTZ
OVERALL LENGTH 1.050 INCHES MINIMUM AND 1.090 INCHES MAXIMUM
OVERALL WIDTH 0.300 INCHES NOMINAL
OVERALL HEIGHT 1.050 INCHES MINIMUM AND 1.090 INCHES MAXIMUM
CONNECTOR QUANTITY 2
CONTROLLING AGENCY SIERRA MICROWAVE TECHNOLOGY, 1CY63
INSERTION LOSS IN DECIBELS 0.4
SPECIAL FEATURES VSWR 1.25:1 MAX; TEMPERATURE OPERATING M40.0 TO P60.0 DEG C, STORAGE M55.0 TO P100.0 DEG C; PHASE TRACKING WITHIN 5 DEG; POWER 30 WATTS CW, 1KW PEAK
III USAGE DESIGN 3D RADAR, D BAND, LONG RANGE
III PART NAME ASSIGNED BY CONTROLLING AGENCY DROP-IN CIRCULATOR

Restrictions/Controls & Freight Information | NSN 5985-01-547-9640

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information