Product Details | DIPLEXER

5985-01-588-0317 An item designed to allow a single antenna to be used for simultaneous transmission and reception on different frequencies. It is installed in a transmission line or waveguide system between the transmitter(s) and/or receivers and a common antenna. It may have provisions for tuning.

Part Alternates: BOM07056, KN003058, 5985-01-588-0317, 01-588-0317, 5985015880317, 015880317

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 30 AUG 2010 01-588-0317

Cross Reference | NSN 5985-01-588-0317

Part Number Cage Code Manufacturer
BOM07056 67195 SPECTRUM FSY MICROWAVE, INC. DIV API TECHNOLOGIES CORP. -
KN003058 34228 L-3 COMMUNICATIONS CORPORATION DBA L-3 KEO

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-01-588-0317

Technical Data | NSN 5985-01-588-0317

Characteristic Specifications
SPECIAL FEATURES ALUMINUM ALLOY, NICKEL PLATE FINISH; CH. 1 1.L. 2.0 DB MAX OVER 1200 TO 1600MHZ, VSWR 2:1, 40 DBC MIN. AT 2000 TO 18000MHZ; CH. 2 1.L. 2.0DB MAX OVER 2000 TO 18000MHZ, VSWR 2:1, 40 DBC MIN. AT 1200 TO 1600MHZ; SMA FEMALE CONNECTORS, TEMP RANGE: 0-60 DEG. C
OVERALL LENGTH 2.000 INCHES NOMINAL
OVERALL WIDTH 0.380 INCHES NOMINAL
TRANSMISSION LINE TYPE COAXIAL CABLE
OVERALL HEIGHT 0.380 INCHES NOMINAL
OPERATING FREQUENCY 1200.0 MEGAHERTZ MINIMUM AND 18000.0 MEGAHERTZ MAXIMUM
PART NAME ASSIGNED BY CONTROLLING AGENCY DIPLEXER

Restrictions/Controls & Freight Information | NSN 5985-01-588-0317

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information