Product Details | WAVEGUIDE SWITCH

5985-01-615-0011 An item specifically designed for mechanically or electronically positioning one or more waveguide sections so as to couple it or them to other sections in a waveguide system. The switching function may be operated by a manual actuator, an electromechanical actuator or by means of an arrangement of semiconductors and passive circuit devices. Excludes RELAY, (as modified).

Part Alternates: SMS17391, SMS-1739-1 , 5985-01-615-0011, 01-615-0011, 5985016150011, 016150011

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 2012356 01-615-0011

Cross Reference | NSN 5985-01-615-0011

Part Number Cage Code Manufacturer
SMS-1739-1 53263 SECTOR MICROWAVE INDUSTRIES, INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-01-615-0011

Technical Data | NSN 5985-01-615-0011

Characteristic Specifications
III FREQUENCY RATING 2.6 GIGAHERTZ NOMINAL AND
RF POWER HANDLING CAPABILITY 1500.0 WATTS AVERAGE SINGLE
VOLTAGE STANDING WAVE RATIO 1.0 SINGLE
INSERTION LOSS IN DECIBELS 0.10 SINGLE
MINIMUM CROSSTALK RATING IN DECIBELS 80.0 SINGLE
ACTUATOR OPERATING METHOD RELAY
ACTUATOR VOLTAGE IN VOLTS 48.0 NOMINAL
SWITCHING TIME 200.0 MILLISECONDS
BODY STYLE RECTANGULAR
OVERALL LENGTH 9.200 INCHES MAXIMUM
OVERALL HEIGHT 4.250 INCHES NOMINAL
OVERALL WIDTH 4.250 INCHES NOMINAL
PART NAME ASSIGNED BY CONTROLLING AGENCY WR284 SEALED WAVEGUIDE SWITCH
III END ITEM IDENTIFICATION RDA, NEXRAD

Restrictions/Controls & Freight Information | NSN 5985-01-615-0011

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information