Product Details | ELECTRICAL CORD ASSEMBLY

5995-01-108-1197 A definite length of CORD, ELECTRICAL having one or both ends processed and/or terminated in fittings which provide for connection to another item. It is generally used with telephone and communication equipment, such as headsets, category cable and switchboard patch cable. See also CABLE ASSEMBLY, (as modified and LEAD (as modified.

Part Alternates: 1398421, 139842-1, 5995-01-108-1197, 01-108-1197, 5995011081197, 011081197

Electrical and Electronic Equipment Components | Cable, Cord, and Wire Assemblies: Communication Equipment

Supply Group (FSG) NSN Assign. NIIN
59 21 FEB 1981 01-108-1197

Drawings & Photos | NSN 5995-01-108-1197


Demand History | NSN 5995-01-108-1197

Part Number Request Date QTY Origin
139842-1 2025-10-275 1 DIBBS
139842-1 2023-09-269 2 DIBBS
139842-1 2023-09-257 2 DIBBS
139842-1 2023-06-164 2 DIBBS

Cross Reference | NSN 5995-01-108-1197

Part Number Cage Code Manufacturer
139842-1 3B150 RAYTHEON TECHNICAL SERVICES COMPANY LLC
139842-1 49956 RAYTHEON COMPANY DBA RAYTHEON

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5995-01-108-1197

Technical Data | NSN 5995-01-108-1197

Characteristic Specifications
CONDUCTOR QUANTITY 4
CONDUCTOR FORM STRANDED ALL CONDUCTORS
MATERIAL COPPER CORE CONDUCTOR ALL CONDUCTORS RUBBER CHLOROPRENE CLASS CR 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS RUBBER SYNTHETIC 1ST POSITION JACKET CORD
MATERIAL DOCUMENT AND CLASSIFICATION QQ-W-343,SOFT FED SPEC SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS
ROUND CONDUCTOR SIZE 22 AWG ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR 16 ALL CONDUCTORS
STRAND AWG SIZE PER CONDUCTOR 34 ALL CONDUCTORS
CONDUCTOR ARRANGEMENT AND QUANTITY 4 SINGLES
STYLE DESIGNATOR 58 EXTERNAL CONNECTOR
EXTENDED LENGTH 12.000 INCHES
RETRACTED LENGTH 2.000 INCHES
CROSS-SECTIONAL SHAPE STYLE 1 COIL/CORD
CROSS SECTION OUTSIDE DIAMETER 0.312 INCHES NOMINAL
TERMINATION TYPE STRIPPED BOTH ENDS ALL CONDUCTORS
MANUFACTURERS CODE 3B150
DESIGN CONTROL REFERENCE 139842-1

Restrictions/Controls & Freight Information | NSN 5995-01-108-1197

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061130 CABLE ASSEMBLY
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 743 unknown
Originating Activity Code CX Defense Supply Center Richmond
Richmond, VA 23297-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5995-01-108-1197

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each