Product Details | RADIO FREQUENCY CABLE ASSEMBLY

5995-01-151-5825 A definite length of CABLE, RADIO FREQUENCY having one or both ends processed and/or terminated in fittings which provide for connection to other items. Includes multiple cable assemblies in a common jacket or shield. Excludes items having branches or forks and LEAD, TEST. See also CABLE ASSEMBLY, RADIO FREQUENCY, BRANCHED.20211350043Fuzing and Firing Devices, Nuclear Ordnance59950057Cable, Cord, and Wire Assemblies: Communication Equipment

Part Alternates: 211110000REVA, 211110-000REVA, 5995-01-151-5825, 01-151-5825, 5995011515825, 011515825

Electrical and Electronic Equipment Components | Cable, Cord, and Wire Assemblies: Communication Equipment

Supply Group (FSG) NSN Assign. NIIN
59 19 APR 1983 01-151-5825

Drawings & Photos | NSN 5995-01-151-5825


Cross Reference | NSN 5995-01-151-5825

Part Number Cage Code Manufacturer
211110-000REVA 81413 BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION I

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5995-01-151-5825

Technical Data | NSN 5995-01-151-5825

Characteristic Specifications
CONDUCTOR QUANTITY 1
CONDUCTOR FORM STRANDED SINGLE CONDUCTOR
MATERIAL STEEL 1ST POSITION CONDUCTOR SINGLE CONDUCTOR PLASTIC POLYTETRAFLUOROETHYLENE 1ST POSITION PRIMARY INSULATION SINGLE CONDUCTOR COPPER 2ND POSITION CONDUCTOR SINGLE CONDUCTOR COPPER ALLOY 2ND POSITION SHIELD BRAID, METALLIC SINGLE CONDUCTOR SILVER 3RD POSITION COVER SINGLE CONDUCTOR PLASTIC FLUORINATED ETHYLENE PROPYLENE 4TH POSITION CONDUCTOR SINGLE CONDUCTOR
MATERIAL DOCUMENT AND CLASSIFICATION QQ-W-345 FED SPEC ALL MATERIAL RESPONSES 1ST POSITION CONDUCTOR SINGLE CONDUCTOR MIL-C-17 MIL SPEC SINGLE MATERIAL RESPONSE 2ND POSITION COVER SINGLE CONDUCTOR
SURFACE TREATMENT SILVER CORE CONDUCTOR SINGLE CONDUCTOR
ROUND CONDUCTOR SIZE 25 AWG SINGLE CONDUCTOR
STRAND QUANTITY PER CONDUCTOR 7 SINGLE CONDUCTOR
STRAND AWG SIZE PER CONDUCTOR 33 SINGLE CONDUCTOR
CONDUCTOR ARRANGEMENT AND QUANTITY 1 COAXIAL
ELECTRICAL RESISTANCE 50.00 OHMS IMPEDANCE
STYLE DESIGNATOR 40 INTERNAL AND EXTERNAL CONNECTOR
OVERALL LENGTH 9.000 INCHES
CROSS-SECTIONAL SHAPE STYLE 6 ROUND
CROSS SECTION OUTSIDE DIAMETER 0.098 INCHES NOMINAL
TEMP RATING -55.0 DEG CELSIUS AND 200.0 DEG CELSIUS
TERMINATION TYPE CONNECTOR PLUG BOTH ENDS SINGLE CONDUCTOR
TERMINAL MANUFACTURER IDENTIFYING REFERENCE NUMBER 195724-000 1ST END ALL CONDUCTORS 195724-000 2ND END ALL CONDUCTORS
TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE 81413 BOTH ENDS SINGLE CONDUCTOR
SPECIAL FEATURES M17/113-RG316CABLE
III PRECIOUS MATERIAL SILVER
III PRECIOUS MATERIAL AND WEIGHT 0.040 SILVER GRAINS, TROY
III PRECIOUS MATERIAL AND LOCATION CONDUCTOR SILVER
MANUFACTURERS CODE 81413
DESIGN CONTROL REFERENCE 211110-000REVA

Restrictions/Controls & Freight Information | NSN 5995-01-151-5825

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:SItem contains silver
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061320 COAXIAL TRANSMISSION LINE/FITTINGS
Less than car load rating
Less than truck load rating J 100.2
Water commodity Code 658 unknown
Originating Activity Code CX Defense Supply Center Richmond
Richmond, VA 23297-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5995-01-151-5825

Category Code Description
Cognizance Codes9GNavy-owned stocks of defense general material
Naval Inventory Control Point, Mechanicsburg
Source of SupplyS9GDefense Supply Center Richmond
Richmond, VA 23297
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each