Product Details | INTERMEDIATE FREQUENCY AMPLIFIER

5996-00-067-5219 An electronic device whose input signals controls a local source of power and delivers an output signal of greater amplitude with respect to current and/or voltage. The output signals characteristics are uniformly related to the input signals. It is tuned to a single fixed frequency which is the resultant of heterodyne action between a local oscillator frequency and a signal frequency introduced from an external source.

Part Alternates: 5535505005, 553-5505-005, 5996-00-067-5219, 00-067-5219, 5996000675219, 000675219

Electrical and Electronic Equipment Components | Amplifiers

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1963 00-067-5219

Drawings & Photos | NSN 5996-00-067-5219


Cross Reference | NSN 5996-00-067-5219

Part Number Cage Code Manufacturer
553-5505-005 13499 ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5996-00-067-5219

Technical Data | NSN 5996-00-067-5219

Characteristic Specifications
FREQUENCY PER CHANNEL 455.0 KILOHERTZ NOMINAL INPUT CHANNEL
SIGNAL VOLTAGE RATING PER CHANNEL 700.000 MILLIVOLTS NOMINAL INPUT
OVERALL GAIN NOT RATED
IMPEDANCE RATING PER CHANNEL 70.000 OHMS INPUT CHANNEL 1.000 MEGOHMS OUTPUT CHANNEL
EXTERNAL DC OPERATING VOLTAGE IN VOLTS 28.0 NOMINAL SINGLE VOLTAGE
BASIC SHAPE STYLE 1 RECTANGULAR OR SQUARE
OVERALL LENGTH 6.000 INCHES NOMINAL
OVERALL HEIGHT 0.500 INCHES NOMINAL
OVERALL WIDTH 4.250 INCHES NOMINAL
MANUFACTURERS CODE 13499
DESIGN CONTROL REFERENCE 553-5505-005

Restrictions/Controls & Freight Information | NSN 5996-00-067-5219

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:CMunitions List Item or Commerce Control List Item. Demilitarization required. Remove and/or demilitarize installed key point(s) as prescribed in the Defense Demilitarization Manual, or lethal parts, components and accessories.
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:NThe item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input).
Category Code Description
NMF Description 063035 SETS RADIO/TV AND RELATED ARTICLES
Less than car load rating
Less than truck load rating G 125.0
Water commodity Code 738 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5996-00-067-5219

Category Code Description
Materiel Management Aggregation CodeCWTG:AIRBORNE RADAR AND MISCELLANEOUS ELECTRONIC EQUIPMENT
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplyFLZWarner Robins Air Logistics Center
Robins AFB, GA 31098-5609
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each