NSN 5996-00-109-8172 A450001, A45000-1, 00-109-8172
Product Details | RADIO FREQUENCY AMPLIFIER
5996-00-109-8172 An electronic device whose radio frequency input signals control power from a source independent of the input signals, and delivers radio frequency output signals of greater amplitude with respect to current and/or voltage. The output signals characteristics are uniformly related to the input signals. It operates at frequencies above 20 kilohertz.202598500005996000000
Part Alternates: A450001, A45000-1, 5996-00-109-8172, 00-109-8172, 5996001098172, 001098172
Electrical and Electronic Equipment Components | Amplifiers
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 02 AUG 1968 | 00-109-8172 | 00446 ( AMPLIFIER, RADIO FREQUENCY ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5996-00-109-8172
Related Products | NSN 5996-00-109-8172
Technical Data | NSN 5996-00-109-8172
| Characteristic | Specifications |
|---|---|
| CIRCUIT CONSTRUCTION TYPE | SOLID STATE |
| FREQUENCY PER CHANNEL | 30.0 MEGAHERTZ NOMINAL INPUT CHANNEL AND 120.0 MEGAHERTZ NOMINAL OUTPUT CHANNEL |
| ATTENUATION IN DECIBELS | NOT RATED |
| AVERAGE POWER RATING PER CHANNEL | NOT RATED |
| SIGNAL VOLTAGE RATING PER CHANNEL | 0.100 VOLTS NOMINAL INPUT 70.000 MILLIVOLTS MINIMUM OUTPUT |
| OVERALL GAIN | NOT RATED |
| IMPEDANCE RATING PER CHANNEL | 50.000 OHMS INPUT CHANNEL 50.000 OHMS OUTPUT CHANNEL |
| OPERATING CONTROL METHOD | AUTOMATIC |
| CONTROL TYPE | REMOTE |
| MAXIMUM CONTINUOUS OPERATING TIME IN HOURS | NOT RATED |
| AVERAGE LIFE MEASUREMENT | NOT RATED |
| MAXIMUM OPERATING ALTITUDE RATING | NOT RATED |
| OPERATING TEMP RANGE | -40.0 TO 85.0 DEG CELSIUS |
| EXTERNAL DC OPERATING VOLTAGE IN VOLTS | 14.25 MINIMUM SINGLE VOLTAGE AND 15.75 MAXIMUM SINGLE VOLTAGE |
| CONNECTION TYPE AND LOCATION | SOLDER LUG LEFT SIDE AND SOLDER LUG RIGHT SIDE |
| CONNECTION CONTACT TYPE AND QUANTITY | 3 SOLDER LUG EXTERNAL AND 2 TERMINAL STUD EXTERNAL |
| INCLOSURE TYPE | ENCASED |
| INSTALLATION DESIGN | MECHANICAL |
| BASIC SHAPE STYLE | 1 RECTANGULAR OR SQUARE |
| OVERALL LENGTH | 3.009 INCHES MAXIMUM |
| OVERALL HEIGHT | 0.618 INCHES MAXIMUM |
| OVERALL WIDTH | 0.625 INCHES NOMINAL |
| SPECIAL FEATURES | TWO MTG STUDS |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| III END ITEM IDENTIFICATION | RECEIVING SET,RADIO AN/GRR-17 |
| III FSC APPLICATION DATA | COMMUNICATION EQUIPMENT,MISCELLANEOUS |
Restrictions/Controls & Freight Information | NSN 5996-00-109-8172
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | C | Munitions List Item or Commerce Control List Item. Demilitarization required. Remove and/or demilitarize installed key point(s) as prescribed in the Defense Demilitarization Manual, or lethal parts, components and accessories. |
| Controlled Inventory Item Code: | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| NMF Description | 063035 | SETS RADIO/TV AND RELATED ARTICLES |
| Less than car load rating | ||
| Less than truck load rating | G | 125.0 |
| Water commodity Code | 723 | unknown |
| Originating Activity Code | PA | Marine Corps Logistics Base Albany, GA 31704-1128 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5996-00-109-8172
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
| Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |