NSN 5996-00-111-7152 001117152
Product Details | RADIO FREQUENCY AMPLIFIER
5996-00-111-7152 An electronic device whose radio frequency input signals control power from a source independent of the input signals, and delivers radio frequency output signals of greater amplitude with respect to current and/or voltage. The output signals characteristics are uniformly related to the input signals. It operates at frequencies above 20 kilohertz.202598500005996000000
Part Alternates: 001117152
Communication, Detection, and Coherent Radiation Equipment | Miscellaneous Communication Equipment
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 58 | 00-111-7152 | 00446 ( AMPLIFIER, RADIO FREQUENCY ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5996-00-111-7152
Related Products | NSN 5996-00-111-7152
Technical Data | NSN 5996-00-111-7152
| Characteristic | Specifications |
|---|---|
| CIRCUIT CONSTRUCTION TYPE | ELECTRON TUBE |
| FREQUENCY PER CHANNEL | 2.0 MEGAHERTZ MINIMUM INPUT CHANNEL 29.9999 MEGAHERTZ MAXIMUM INPUT CHANNEL 2.0 MEGAHERTZ MINIMUM OUTPUT CHANNEL 29.9999 MEGAHERTZ MAXIMUM OUTPUT CHANNEL |
| ATTENUATION IN DECIBELS | NOT RATED |
| AVERAGE POWER RATING PER CHANNEL | 200.0 MILLIWATTS INPUT 500.0 WATTS OUTPUT |
| SIGNAL VOLTAGE RATING PER CHANNEL | NOT RATED |
| OVERALL GAIN | NOT RATED |
| IMPEDANCE RATING PER CHANNEL | 50.000 OHMS INPUT CHANNEL 50.000 OHMS OUTPUT CHANNEL |
| OPERATING CONTROL METHOD | MANUAL |
| CONTROL TYPE | LOCAL OR REMOTE |
| MAXIMUM CONTINUOUS OPERATING TIME IN HOURS | NOT RATED |
| AVERAGE LIFE MEASUREMENT | NOT RATED |
| MAXIMUM OPERATING ALTITUDE RATING | NOT RATED |
| OPERATING TEMP RANGE | -40.0 TO 55.0 DEG CELSIUS |
| VIBRATION RESISTANCE RANGE IN HERTZ | NOT RATED |
| SHOCK RESISTANCE RATING IN GRAVITATIONAL UNITS | NOT RATED |
| EXTERNAL AC OPERATING VOLTAGE IN VOLTS | 115.0 NOMINAL SINGLE VOLTAGE |
| OPERATING AC FREQUENCY IN HERTZ | 400.0 NOMINAL SINGLE VOLTAGE |
| PHASE | SINGLE |
| BASIC SHAPE STYLE | 1 RECTANGULAR OR SQUARE |
| OVERALL LENGTH | 13.357 INCHES NOMINAL |
| OVERALL HEIGHT | 4.334 INCHES NOMINAL |
| OVERALL WIDTH | 7.302 INCHES NOMINAL |
| FEATURES PROVIDED | AUTOMATIC GAIN CONTROL |
| MANUFACTURERS CODE | 13499 |
| DESIGN CONTROL REFERENCE | 528-0687-001 |
Restrictions/Controls & Freight Information | NSN 5996-00-111-7152
| Category | Code | Description |
|---|---|---|
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Controlled Inventory Item Code: | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||