NSN 5996-00-111-7194 C5138987, C5138-987, 00-111-7194
Product Details | RADIO FREQUENCY AMPLIFIER
5996-00-111-7194 An electronic device whose radio frequency input signals control power from a source independent of the input signals, and delivers radio frequency output signals of greater amplitude with respect to current and/or voltage. The output signals characteristics are uniformly related to the input signals. It operates at frequencies above 20 kilohertz.202598500005996000000
Part Alternates: C5138987, C5138-987, 5996-00-111-7194, 00-111-7194, 5996001117194, 001117194
Electrical and Electronic Equipment Components | Amplifiers
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 28 AUG 1968 | 00-111-7194 | 00446 ( AMPLIFIER, RADIO FREQUENCY ) |
Demand History | NSN 5996-00-111-7194
| Part Number | Request Date | QTY | Origin |
|---|---|---|---|
| C5138-987 | 2024-07-204 | 9 | DIBBS |
| C5138-987 | 2024-07-192 | 9 | DIBBS |
| C5138-987 | 2023-12-360 | 5 | DIBBS |
| C5138-987 | 2023-12-348 | 5 | DIBBS |
| C5138-987 | 2023-11-317 | 6 | DIBBS |
| C5138-987 | 2023-11-306 | 6 | DIBBS |
| C5138-987 | 2023-05-125 | 6 | DIBBS |
| C5138-987 | 2023-04-96 | 6 | DIBBS |
| C5138-987 | 2022-02-32 | 3 | DIBBS |
| C5138-987 | 2020-10-294 | 6 | DIBBS |
| C5138-987 | 2020-09-261 | 1 | DIBBS |
| C5138-987 | 2020-07-211 | 2 | DIBBS |
| C5138-987 | 2019-12-340 | 11 | DIBBS |
| C5138-987 | 2019-11-329 | 11 | DIBBS |
| C5138-987 | 2019-11-317 | 11 | DIBBS |
| C5138-987 | 2019-05-133 | 9 | DIBBS |
| C5138-987 | 2019-05-122 | 9 | DIBBS |
| 5996-00-111-7194 | 2017-05-131 | 8 | DIBBS |
| 5996-00-111-7194 | 2017-04-120 | 8 | DIBBS |
| 5996-00-111-7194 | 2014-09-253 | 12 | DIBBS |
| 5996-00-111-7194 | 2013-02-32 | 9 | DIBBS |
| 5996-00-111-7194 | 2013-01-09 | 2 | DIBBS |
| 5996-00-111-7194 | 2012-12-362 | 2 | DIBBS |
| 5996-00-111-7194 | 2009-01-06 | 4 | DIBBS |
| 5996-00-111-7194 | 2008-08-243 | 12 | DIBBS |
Cross Reference | NSN 5996-00-111-7194
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5996-00-111-7194
Related Products | NSN 5996-00-111-7194
Technical Data | NSN 5996-00-111-7194
| Characteristic | Specifications |
|---|---|
| FREQUENCY PER CHANNEL | 4.9 MEGAHERTZ MINIMUM INPUT CHANNEL 5.1 MEGAHERTZ MAXIMUM INPUT CHANNEL 4.9 MEGAHERTZ MINIMUM OUTPUT CHANNEL 5.1 MEGAHERTZ MAXIMUM OUTPUT CHANNEL |
| FREQUENCY ADJUSTMENT TYPE | CONTINUOUS |
| ATTENUATION IN DECIBELS | NOT RATED |
| AVERAGE POWER RATING PER CHANNEL | 20.0 MILLIWATTS OUTPUT |
| SIGNAL VOLTAGE RATING PER CHANNEL | 500.000 MILLIVOLTS MINIMUM INPUT 5.000 VOLTS MAXIMUM INPUT 950.000 MILLIVOLTS MINIMUM OUTPUT 1.050 VOLTS MAXIMUM OUTPUT |
| OVERALL GAIN | NOT RATED |
| IMPEDANCE RATING PER CHANNEL | 50.000 OHMS INPUT CHANNEL 50.000 OHMS OUTPUT CHANNEL |
| OPERATING CONTROL METHOD | AUTOMATIC |
| MAXIMUM CONTINUOUS OPERATING TIME IN HOURS | NOT RATED |
| AVERAGE LIFE MEASUREMENT | NOT RATED |
| MAXIMUM OPERATING ALTITUDE RATING | NOT RATED |
| OPERATING TEMP RANGE | 0.0 TO 50.0 DEG CELSIUS |
| VIBRATION RESISTANCE RANGE IN HERTZ | NOT RATED |
| SHOCK RESISTANCE RATING IN GRAVITATIONAL UNITS | NOT RATED |
| EXTERNAL DC OPERATING VOLTAGE IN VOLTS | 20.0 NOMINAL SINGLE VOLTAGE |
| INCLOSURE TYPE | ENCASED |
| INSTALLATION DESIGN | MECHANICAL |
| BASIC SHAPE STYLE | 1 RECTANGULAR OR SQUARE |
| OVERALL LENGTH | 4.000 INCHES NOMINAL |
| OVERALL HEIGHT | 0.718 INCHES NOMINAL |
| OVERALL WIDTH | 3.070 INCHES NOMINAL |
| MANUFACTURERS CODE | 14844 |
| DESIGN CONTROL REFERENCE | C5138-987 |
Restrictions/Controls & Freight Information | NSN 5996-00-111-7194
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | C | Munitions List Item or Commerce Control List Item. Demilitarization required. Remove and/or demilitarize installed key point(s) as prescribed in the Defense Demilitarization Manual, or lethal parts, components and accessories. |
| Controlled Inventory Item Code: | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| NMF Description | 063035 | SETS RADIO/TV AND RELATED ARTICLES |
| Less than car load rating | ||
| Less than truck load rating | G | 125.0 |
| Water commodity Code | 723 | unknown |
| Originating Activity Code | HH | Navy ICP Mechanicsburg, PA 17055-0788 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5996-00-111-7194
| Category | Code | Description |
|---|---|---|
| Budget Code | 9 | General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors. |
| Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
| Fund Code | SF | Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point. |
| Materiel Management Aggregation Code | TG | TG:AF SICA RESIDUAL MMAC-WR-ALC |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DF | Department of the Air Force |
| Service Organization | F | U.S. Air Force |
| Reparability | N | Stock Fund (except Munitions) |
| Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
| Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 3B | Navy-owned stocks of field level repairable DLA material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Reparability | D | Field Level Reparables |
| Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
| Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |