Product Details | AUDIO FREQUENCY AMPLIFIER

5996-01-279-3903 An electronic device whose audio frequency input signals control power from a source independant of the input signal and delivers audio frequency output signals of greater amplitude with respect to current and/or voltage. The output signals characteristics are uniformly related to the input signals. It operates at frequencies of 20 kilohertzs and below. It may or may not have signal switching capabilities.

Part Alternates: HTA125A, HTA-125A, 9012PW/CRH01S, 9012PWCRH01S, A150, 5996-01-279-3903, 01-279-3903, 5996012793903, 012793903

Electrical and Electronic Equipment Components | Amplifiers

Supply Group (FSG) NSN Assign. NIIN
59 18 MAY 1988 01-279-3903

Drawings & Photos | NSN 5996-01-279-3903


Demand History | NSN 5996-01-279-3903

Part Number Request Date QTY Origin
5996-01-279-3903 2018-09-260 1 DIBBS
5996-01-279-3903 2017-09-262 5 DIBBS
5996-01-279-3903 2016-07-209 1 DIBBS
5996-01-279-3903 2011-06-175 1 DIBBS
5996-01-279-3903 2009-10-283 3 DIBBS

Cross Reference | NSN 5996-01-279-3903

Part Number Cage Code Manufacturer
9012PW/CRH01S 87771 UNIVERSITY SOUND INC AFFIL OF MARK IV INDUSTRIES INC
A150 87771 UNIVERSITY SOUND INC AFFIL OF MARK IV INDUSTRIES INC
HTA-125A 07843 BOGEN COMMUNICATIONS INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5996-01-279-3903

Technical Data | NSN 5996-01-279-3903

Characteristic Specifications
CIRCUIT CONSTRUCTION TYPE SOLID STATE
AVERAGE POWER RATING PER CHANNEL 125.0 WATTS OUTPUT
OPERATING TEMP RANGE -20.0 TO 55.0 DEG CELSIUS
EXTERNAL AC OPERATING VOLTAGE IN VOLTS 120.0 NOMINAL SINGLE VOLTAGE
OPERATING AC FREQUENCY IN HERTZ 60.0 NOMINAL SINGLE VOLTAGE
BASIC SHAPE STYLE 1 RECTANGULAR OR SQUARE
OVERALL LENGTH 19.000 INCHES NOMINAL
OVERALL HEIGHT 5.250 INCHES NOMINAL
OVERALL WIDTH 11.000 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 5996-01-279-3903

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 063035 SETS RADIO/TV AND RELATED ARTICLES
Less than car load rating
Less than truck load rating G 125.0
Water commodity Code 658 unknown
Originating Activity Code ZC Canada
ZD
ZE
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5996-01-279-3903

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each