Product Details | RADIO FREQUENCY AMPLIFIER

5996-01-506-9273 An electronic device whose radio frequency input signals control power from a source independent of the input signals, and delivers radio frequency output signals of greater amplitude with respect to current and/or voltage. The output signals characteristics are uniformly related to the input signals. It operates at frequencies above 20 kilohertz.202598500005996000000

Part Alternates: DB970001R1, DB97-0001R1, 5996-01-506-9273, 01-506-9273, 5996015069273, 015069273

Electrical and Electronic Equipment Components | Amplifiers

Supply Group (FSG) NSN Assign. NIIN
59 14 APR 2003 01-506-9273

Cross Reference | NSN 5996-01-506-9273

Part Number Cage Code Manufacturer
DB97-0001R1 0ZAJ1 L3 COMMUNICATIONS - DBS MICROWAVE

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5996-01-506-9273

Technical Data | NSN 5996-01-506-9273

Characteristic Specifications
SPECIAL FEATURES 6.0 GHZ FREQUENCY RESPONSE WITH 42.0 DB. GAIN; 9.0 GHZ FREQUENCY RESPONSE WITH A 43.2 DB GAIN; 12.0 GHZ FREQUENCY RESPONSE WITH A 41.3 DB GAIN; 15.0 GHZ FREQUENCY RESPONSE WITH A 41.8 DB GAIN; 18.0 GHZ FREQUENCY RESPONSE WITH A 42.2 DB GAIN; PLUS 12 TO PLUS 15 VDC SUPPLY VOLTAGE; CURRENT 1905MA; ALL MEASUREMENTS AT PLUS 25 DEG. C

Restrictions/Controls & Freight Information | NSN 5996-01-506-9273

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information