Product Details | MAGNETIC AMPLIFIER

5996-01-557-4160 An item consisting of a saturable reactor which is specially designed to be used in conjunction with a rectifier(s) for amplification purposes. The rectifier(s) may or may not be an integral part of the item of supply. The item may include resistors, capacitors, and/or other electrical components.

Part Alternates: 92244, 92-244, 5996-01-557-4160, 01-557-4160, 5996015574160, 015574160

Electrical and Electronic Equipment Components | Amplifiers

Supply Group (FSG) NSN Assign. NIIN
59 22 OCT 2007 01-557-4160

Cross Reference | NSN 5996-01-557-4160

Part Number Cage Code Manufacturer
92-244 4N3X7 COX INSTRUMENTS LLC DBA EXACT FLOW

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5996-01-557-4160

Technical Data | NSN 5996-01-557-4160

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 5 TERMINAL BLOCK W/SCREWS
WINDING OPERATING VOLTAGE 5.00 DC VOLTS MINIMUM AND 28.00 DC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
SATURATION CURRENT RATING 15.0 MILLIAMPERES
FREQUENCY RATING 0.1 KILOHERTZ MINIMUM AND 10.0 KILOHERTZ MAXIMUM SINGLE COMPONENT
MOUNTING METHOD TERMINAL SINGLE GROUP
MOUNTING FACILITY QUANTITY 5 SINGLE GROUP
MOUNTING TAB WIDTH 1.250 INCHES NOMINAL
BODY LENGTH 4.000 INCHES NOMINAL
SPECIAL FEATURES OUPUT VOLTAGE 10VP-P; -20 TO 160 F OPERATING TEMP; 100 FT MAX DISTANCE FROM PICK-OFF TO PRE-AMP; CLASS I, II AND III EXPLOSION PROOF RATING; DESIGNED TO CONVERT LOW LEVEL SIGNALS INTO STABLE SQUARE WAVE PULSE
III PART NAME ASSIGNED BY CONTROLLING AGENCY MAGNETIC PICK-OFF AMPLIFIER

Restrictions/Controls & Freight Information | NSN 5996-01-557-4160

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information