NSN 5999-00-136-9064 A10015, BP2063, SIB1462
Product Details | ELECTRICAL CONTACT ASSEMBLY
5999-00-136-9064 Two or more CONTACT, ELECTRICAL on a common mounting or mounted on each other. Excludes BRUSH SET, ELECTRICAL CONTACT; CONTACT SET (as modified); and INSERT, ELECTRICAL CONNECTOR.
Part Alternates: A10015, BP2063, SIB1462, SIB-1462, SMC697502, SM-C-697502, DM1024, DM-1024, 232800011000, 232-800011-000, 5999-00-136-9064, 00-136-9064, 5999001369064, 001369064
Electrical and Electronic Equipment Components | Miscellaneous Electrical and Electronic Components
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 24 JUL 1971 | 00-136-9064 | 06160 ( CONTACT ASSEMBLY, ELECTRICAL ) |
Cross Reference | NSN 5999-00-136-9064
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 232-800011-000 | 90073 | CMC ELECTRONICS INC |
| A10015 | 05584 | AUTODYNE MANUFACTURING CO., INC. |
| BP2063 | 27361 | BURKE PRODUCTS, INC. |
| DM-1024 | 03TF2 | TRIANGLE TOOL CO |
| DM-1024 | 58017 | COBRA INDUSTRIES INC |
| SIB-1462 | 65884 | SIGMATION INC |
| SM-C-697502 | 20723 | VALCORE MANUFACTURING LLC DBA USE CAGE CODE 04YE2 FOR |
| SM-C-697502 | 27361 | BURKE PRODUCTS, INC. |
| SM-C-697502 | 55097 | SHILOH INDUSTRIES, INC. |
| SM-C-697502 | 80063 | US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5999-00-136-9064
Related Products | NSN 5999-00-136-9064
Technical Data | NSN 5999-00-136-9064
| Characteristic | Specifications |
|---|---|
| STRUCTURAL DESIGN | NONSWITCHING |
| CONTACT QUANTITY | 2 |
| GOVERNMENT AGENCY CONTROLLING CONTACT | USA |
| CONTACT ITEM NAME ASSIGNED BY GOVERNMENT AGENCY | CONTACT ASSY |
| CONTACT IDENTIFYING NUMBER ASSIGNED BY GOVERNMENT AGENCY | SM-C-697502 |
| OVERALL LENGTH | 1.320 INCHES NOMINAL |
| OVERALL DIAMETER | 0.750 INCHES NOMINAL |
Restrictions/Controls & Freight Information | NSN 5999-00-136-9064
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | U | Precious metal type is unknown |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061300 | CIRCUIT BREAKER/SWITCH NOI |
| Less than car load rating | ||
| Less than truck load rating | P | 77.5 |
| Water commodity Code | 658 | unknown |
| Originating Activity Code | CL | U.S. Army Communications-Electronics Fort Monmouth, NJ 07703-5006 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Y | Protected cargo, other than above, including sensitive cargo requiring hand-to-hand receipt and/or security precautions. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5999-00-136-9064
| Category | Code | Description |
|---|---|---|
| Materiel Category and Inventory Manager | Q | Electronics Materiel (DLA/GSA Items) |
| Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
| Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
| Specific Group/Generic Code | 0 | Medical Materiel |
| Weapons Systems/End Item or Homogeneous Group | 00 | DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item |
| Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DA | Department of the Army |
| Service Organization | A | U.S. Army |
| Reparability | Z | This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item. |
| Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |