Product Details | LIGHT-SWITCH

5999-00-803-1269 An electrical device consisting of a Switch (1) and a light, not intended for illumination but present for the purpose of indication, on a common mounting, separable and capable of functioning individually; or one light and one switch fabricated as a common inseparable body incapable of functioning individually. It may include wall plate or box cover and it may be complete with a box. Excludes push, pull, push-pull, and toggle switches with a lamp mounted integrally in the actuator.

Part Alternates: 5644795, 564479-5, 5999-00-803-1269, 00-803-1269, 5999008031269, 008031269

Electrical and Electronic Equipment Components | Miscellaneous Electrical and Electronic Components

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1962 00-803-1269

Cross Reference | NSN 5999-00-803-1269

Part Number Cage Code Manufacturer
564479-5 59364 HONEYWELL INTERNATIONAL INC. DBA HONEYWELL
564479-5 77068 ALLIED-SIGNAL INC DBA ALLIED-SIGNAL AEROSPACE CO

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5999-00-803-1269

Technical Data | NSN 5999-00-803-1269

Characteristic Specifications
LAMP VOLTAGE RATING IN VOLTS 28.0 NOMINAL
LAMP BASE TYPE ACCOMMODATED MIDGET FLANGED
LAMP BULB SIZE DESIGNATOR T1-3/4
FEATURES PROVIDED LENS
LENS COLOR RED
SPECIAL MARKINGS 2
SWITCH CONTACT ARRANGEMENT 2 TWO CIRCUIT, DOUBLE BREAK/DOUBLE MAKE, ONE POSITION MOMENTARY
SWITCH TYPE PUSH
CURRENT TYPE AND RATING IN AMPS 10.00 DC NOMINAL
OPERATING VOLTAGE IN VOLTS 28.0 NOMINAL
SHAPE AND LOCATION ROUND COVER
MATERIAL AND LOCATION ALUMINUM COVER
SURFACE TREATMENT AND LOCATION ANODIZED COVER
MOUNTING METHOD THREADED BUSHING
MOUNTING FACILITY QUANTITY 1
MOUNTING FACILITY THREAD SIZE 15/32-32 UNS
OVERALL DIAMETER 0.938 INCHES NOMINAL
OVERALL LENGTH 2.310 INCHES NOMINAL
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION RAINTIGHT-NEMA TYPE 3R

Restrictions/Controls & Freight Information | NSN 5999-00-803-1269

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:BESD sensitivity
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 713 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo 3 Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

Management | NSN 5999-00-803-1269

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each