Product Details | FIBER OPTIC MODEM

6030-01-386-9246 A device which accepts optic signals and converts them to electrical or radio frequency. It accommodates voltage and optics and is immune to Electromagnetic Interference (EMI) and Radio Frequency Interference (RFI) that is generated. It connects data terminal equipment to a fiber optic transmission line or network.

Part Alternates: 200001, 2000-01, 90001671-1, 6030-01-386-9246, 01-386-9246, 6030013869246, 013869246, 900016711

Fiber Optics Materials, Components, Assemblies, and Accessories | Fiber Optic Devices

Supply Group (FSG) NSN Assign. NIIN
60 18 FEB 1994 01-386-9246

Demand History | NSN 6030-01-386-9246

Part Number Request Date QTY Origin
200001 2021-05-132 2 United States
200001 2018-02-52 1 United States

Cross Reference | NSN 6030-01-386-9246

Part Number Cage Code Manufacturer
2000-01 62787 LITTON NETWORK ACCESS SYSTEMS LITTON ACQUIRED BY NORTHROP GRUMMAN
90001671-1 47956 A C C INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6030-01-386-9246

Technical Data | NSN 6030-01-386-9246

Characteristic Specifications
SPECIAL FEATURES CONVERTS SERIAL BINARY DATA, RS-232, SIGNALS INTO AN OPTICAL SIGNAL FORTRANSMISSION OVER OPTICAL FIBER. EACH MODEM IS PROVIDED POWER FROM AN EXTER OR AC ADAPTER
III END ITEM IDENTIFICATION UHF TRNG AUGMT DEVICE
MANUFACTURERS CODE 62787
DESIGN CONTROL REFERENCE 2000-01

Restrictions/Controls & Freight Information | NSN 6030-01-386-9246

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 057770 CABLE LIGHTGUIDE/WAVE GLASS FIBRE
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 72D unknown
Originating Activity Code TK HQ AFMC/GLSC 401 SCM/GUMB
Wright-Patterson AFB, OH 45433-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo 3 Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

Management | NSN 6030-01-386-9246

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Price ValidationP The current standard price is the initial negotiated provisioned price.
  • This is the price paid by DoD for the item as the result of price negotiation of the Provisioned Item Order (PIO) or other initial negotiated price.
  • ZOP or Standard Price challenges are permissible but should be supported with adequate justification.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Materiel Management Aggregation CodeSNSU:AF SATELLITE CONTROL NETWORK COMMON USER SUPPORT
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each